From e6ca2d848c9b7b292d22cbf6fe10019ccab72345 Mon Sep 17 00:00:00 2001
From: Chanwoo Choi <cw00.choi@samsung.com>
Date: Tue, 22 Jul 2014 03:04:00 +0100
Subject: [PATCH] ARM: dts: Fix wrong compatible string for Exynos3250 ADC

This patchset fix wrong compatible string for Exynos3250 ADC. Exynos3250 SoC
need to control only special clock for ADC. Exynos SoC except for Exynos3250
has not included special clock for ADC. The exynos ADC driver can control
special clock if compatible string is 'exynos3250-adc-v2'.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Acked-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Tomasz Figa <t.figa@samsung.com>
Acked-by: Kukjin Kim <kgene.kim@samsung.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
---
 arch/arm/boot/dts/exynos3250.dtsi | 5 +++--
 1 file changed, 3 insertions(+), 2 deletions(-)

diff --git a/arch/arm/boot/dts/exynos3250.dtsi b/arch/arm/boot/dts/exynos3250.dtsi
index 3e678fa335bf..aaaac7981200 100644
--- a/arch/arm/boot/dts/exynos3250.dtsi
+++ b/arch/arm/boot/dts/exynos3250.dtsi
@@ -261,10 +261,11 @@
 		};
 
 		adc: adc@126C0000 {
-			compatible = "samsung,exynos-adc-v3";
+			compatible = "samsung,exynos3250-adc",
+				     "samsung,exynos-adc-v2";
 			reg = <0x126C0000 0x100>, <0x10020718 0x4>;
 			interrupts = <0 137 0>;
-			clock-names = "adc", "sclk_tsadc";
+			clock-names = "adc", "sclk";
 			clocks = <&cmu CLK_TSADC>, <&cmu CLK_SCLK_TSADC>;
 			#io-channel-cells = <1>;
 			io-channel-ranges;
-- 
2.20.1