From e06e4c2d530fd4995c41083009647263ccd77d3b Mon Sep 17 00:00:00 2001 From: Oskar Schirmer Date: Mon, 5 Aug 2013 07:36:02 +0000 Subject: [PATCH] ASoC: sgtl5000: fix codec clock source transition to avoid clockless moment Powering down PLL before switching to a mode that does not use it is a bad idea. It would cause the SGTL5000 be without internal clock supply, especially on the I2C interface, which would make subsequent access to it fail. Thus, in case of not using PLL any longer, first set the mode control, then power down PLL. Signed-off-by: Oskar Schirmer Signed-off-by: Mark Brown --- sound/soc/codecs/sgtl5000.c | 9 ++++++--- 1 file changed, 6 insertions(+), 3 deletions(-) diff --git a/sound/soc/codecs/sgtl5000.c b/sound/soc/codecs/sgtl5000.c index 7c99f3ccb1c6..54ca169ec27e 100644 --- a/sound/soc/codecs/sgtl5000.c +++ b/sound/soc/codecs/sgtl5000.c @@ -644,16 +644,19 @@ static int sgtl5000_set_clock(struct snd_soc_codec *codec, int frame_rate) snd_soc_update_bits(codec, SGTL5000_CHIP_ANA_POWER, SGTL5000_PLL_POWERUP | SGTL5000_VCOAMP_POWERUP, SGTL5000_PLL_POWERUP | SGTL5000_VCOAMP_POWERUP); + + /* if using pll, clk_ctrl must be set after pll power up */ + snd_soc_write(codec, SGTL5000_CHIP_CLK_CTRL, clk_ctl); } else { + /* otherwise, clk_ctrl must be set before pll power down */ + snd_soc_write(codec, SGTL5000_CHIP_CLK_CTRL, clk_ctl); + /* power down pll */ snd_soc_update_bits(codec, SGTL5000_CHIP_ANA_POWER, SGTL5000_PLL_POWERUP | SGTL5000_VCOAMP_POWERUP, 0); } - /* if using pll, clk_ctrl must be set after pll power up */ - snd_soc_write(codec, SGTL5000_CHIP_CLK_CTRL, clk_ctl); - return 0; } -- 2.20.1