From ddab1a3b30452bf6d2a2780dbb5fd962a85bec48 Mon Sep 17 00:00:00 2001 From: Nicolas Kaiser Date: Thu, 18 Nov 2010 14:24:02 +0000 Subject: [PATCH] SuperH IrDA: correct Baud rate error correction It looks to me as if the second value of rate_err_array is intended to be a decimal 625. However, with a leading 0 it becomes an octal constant, and as such evaluates to a decimal 405. Signed-off-by: Nicolas Kaiser Signed-off-by: David S. Miller --- drivers/net/irda/sh_sir.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/net/irda/sh_sir.c b/drivers/net/irda/sh_sir.c index 00b38bccd6d..52a7c86af66 100644 --- a/drivers/net/irda/sh_sir.c +++ b/drivers/net/irda/sh_sir.c @@ -258,7 +258,7 @@ static int sh_sir_set_baudrate(struct sh_sir_self *self, u32 baudrate) /* Baud Rate Error Correction x 10000 */ u32 rate_err_array[] = { - 0000, 0625, 1250, 1875, + 0, 625, 1250, 1875, 2500, 3125, 3750, 4375, 5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, -- 2.20.1