From a5eae259db3500d36db601e73a68abb7f7de1ad6 Mon Sep 17 00:00:00 2001 From: Yauhen Kharuzhy Date: Sun, 7 Nov 2021 23:20:01 +0300 Subject: [PATCH] power: bq25890: Enable continuous conversion for ADC at charging [ Upstream commit 80211be1b9dec04cc2805d3d81e2091ecac289a1 ] Instead of one shot run of ADC at beginning of charging, run continuous conversion to ensure that all charging-related values are monitored properly (input voltage, input current, themperature etc.). Signed-off-by: Yauhen Kharuzhy Reviewed-by: Hans de Goede Signed-off-by: Sebastian Reichel Signed-off-by: Sasha Levin --- drivers/power/supply/bq25890_charger.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c index 8e2c41ded171..e90253b3f656 100644 --- a/drivers/power/supply/bq25890_charger.c +++ b/drivers/power/supply/bq25890_charger.c @@ -521,12 +521,12 @@ static void bq25890_handle_state_change(struct bq25890_device *bq, if (!new_state->online) { /* power removed */ /* disable ADC */ - ret = bq25890_field_write(bq, F_CONV_START, 0); + ret = bq25890_field_write(bq, F_CONV_RATE, 0); if (ret < 0) goto error; } else if (!old_state.online) { /* power inserted */ /* enable ADC, to have control of charge current/voltage */ - ret = bq25890_field_write(bq, F_CONV_START, 1); + ret = bq25890_field_write(bq, F_CONV_RATE, 1); if (ret < 0) goto error; } -- 2.20.1