From 888c9c7366cef902531f27f6aa5fb787c86810d4 Mon Sep 17 00:00:00 2001 From: Peter Meerwald Date: Wed, 5 Feb 2014 16:57:00 +0000 Subject: [PATCH] iio: Add ABI documentation for object and ambient modifiers Signed-off-by: Peter Meerwald Signed-off-by: Jonathan Cameron --- Documentation/ABI/testing/sysfs-bus-iio | 7 +++++-- 1 file changed, 5 insertions(+), 2 deletions(-) diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index 6b74691dc281..ca3d3b724efd 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -114,14 +114,17 @@ What: /sys/bus/iio/devices/iio:deviceX/in_temp_raw What: /sys/bus/iio/devices/iio:deviceX/in_tempX_raw What: /sys/bus/iio/devices/iio:deviceX/in_temp_x_raw What: /sys/bus/iio/devices/iio:deviceX/in_temp_y_raw -What: /sys/bus/iio/devices/iio:deviceX/in_temp_z_raw +What: /sys/bus/iio/devices/iio:deviceX/in_temp_ambient_raw +What: /sys/bus/iio/devices/iio:deviceX/in_temp_object_raw KernelVersion: 2.6.35 Contact: linux-iio@vger.kernel.org Description: Raw (unscaled no bias removal etc.) temperature measurement. If an axis is specified it generally means that the temperature sensor is associated with one part of a compound device (e.g. - a gyroscope axis). Units after application of scale and offset + a gyroscope axis). The ambient and object modifiers distinguish + between ambient (reference) and distant temperature for contact- + less measurements. Units after application of scale and offset are milli degrees Celsius. What: /sys/bus/iio/devices/iio:deviceX/in_tempX_input -- 2.20.1