From 0de4adfb8c9674fa1572b0ff1371acc94b0be901 Mon Sep 17 00:00:00 2001 From: Sonic Zhang Date: Mon, 15 Jun 2009 07:39:19 +0000 Subject: [PATCH] Blackfin: fix accidental reset in some boot modes We read the SWRST (Software Reset) register to get at the last reset state, and then we may configure the DOUBLE_FAULT bit to control behavior when a double fault occurs. But if the lower bits of the register is already set (like UART boot mode on a BF54x), we inadvertently make the system reset by writing to the SYSTEM_RESET field at the same time. So make sure the lower 4 bits are always cleared. Signed-off-by: Sonic Zhang Signed-off-by: Mike Frysinger --- arch/blackfin/kernel/setup.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/arch/blackfin/kernel/setup.c b/arch/blackfin/kernel/setup.c index 6454babdfaff..b2782eae31e1 100644 --- a/arch/blackfin/kernel/setup.c +++ b/arch/blackfin/kernel/setup.c @@ -837,7 +837,8 @@ void __init setup_arch(char **cmdline_p) defined(CONFIG_BF538) || defined(CONFIG_BF539) _bfin_swrst = bfin_read_SWRST(); #else - _bfin_swrst = bfin_read_SYSCR(); + /* Clear boot mode field */ + _bfin_swrst = bfin_read_SYSCR() & ~0xf; #endif #ifdef CONFIG_DEBUG_DOUBLEFAULT_PRINT -- 2.20.1