i2c: riic: correctly finish transfers
This fixes the condition where the controller has not fully completed its
final transfer and leaves the bus and controller in a undesirable state.
At the end of the last transmitted byte, the existing driver would just
signal for a STOP condition to be transmitted then immediately signal
completion. However, the full STOP procedure might not have fully taken
place by the time the runtime PM shuts off the peripheral clock, leaving
the bus in a suspended state.
Alternatively, the STOP condition on the bus may have completed, but when
the next transaction is requested by the upper layer, not all the
necessary register cleanup was finished from the last transfer which made
the driver return BUS BUSY when it really wasn't.
This patch now makes all transmit and receive transactions wait for the
STOP condition to fully complete before signaling a completed transaction.
With this new method, runtime PM no longer seems to be an issue.
Fixes:
310c18a41450 ("i2c: riic: add driver")
Signed-off-by: Chris Brandt <chris.brandt@renesas.com>
Reviewed-by: Wolfram Sang <wsa+renesas@sang-engineering.com>