ASoC: fsl: imx-pcm-fiq: remove bogus period delta calculation
authorOskar Schirmer <oskar@scara.com>
Tue, 5 Nov 2013 12:13:54 +0000 (12:13 +0000)
committerMark Brown <broonie@linaro.org>
Wed, 6 Nov 2013 09:41:57 +0000 (09:41 +0000)
commit68f9672b1388f0999d4087b72c3c80cf1c983fa2
tree9335123e1d448d4ae0fce6eac3cdca91f760ff78
parent5a6e19bedb13522924f5ee72c1f65b0fb5d33bc0
ASoC: fsl: imx-pcm-fiq: remove bogus period delta calculation

Originally snd_hrtimer_callback() used iprtd->period_time for
some jiffies based estimation to determine the right moment
to call snd_pcm_period_elapsed(). As timer drifts may well be a
problem, this was changed in commit b4e82b5b785670b6 to be based
on buffer transmission progress, using iprtd->offset and
runtime->buffer_size to calculate the amount of data since last
period had elapsed.

Unfortunately, iprtd->offset counts in bytes, while
runtime->buffer_size counts frames, so adding these to find some
delta is like comparing apples and oranges, and eventually results
in negative delta values every now and then. This is no big harm,
because it simply causes snd_pcm_period_elapsed() being called
more often than necessary, as negative delta is taken for a
large unsigned value by implicit conversion rule.
Nonetheless, the calculation is broken, so one would replace
the runtime->buffer_size by its equivalent in bytes.

But then, there are chances snd_pcm_period_elapsed() is called
late, because calculating the moment for the elapsed period
into delta is based against the iprtd->last_offset, which is not
necessarily the first byte of the period in question, but some
random byte which the FIQ handler left us with in r8/r9 by
accident. Again, negative impact is low, as there are plenty of
periods already prefilled with data, and snd_pcm_period_elapsed()
will probably be called latest when the following period is
reached. However, the calculation is conceptually broken, and we
are best off removing the clever stuff altogether.

snd_pcm_period_elapsed() is now simply called once everytime
snd_hrtimer_callback() is run, which may not be most accurate,
but at least this way we are quite sure we dont miss an end of
period. There is not much extra effort wasted by superfluous
calls to snd_pcm_period_elapsed(), as the timer frequency
closely matches the period size anyway.

Signed-off-by: Oskar Schirmer <oskar@scara.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
sound/soc/fsl/imx-pcm-fiq.c