From: Stefan Richter Date: Sat, 10 May 2008 22:35:04 +0000 (+0200) Subject: firewire: fw-sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares X-Git-Url: https://git.stricted.de/?a=commitdiff_plain;h=ffcaade3109c3a4c0a2c601cf2a44d55b4c3af37;p=GitHub%2FLineageOS%2Fandroid_kernel_motorola_exynos9610.git firewire: fw-sbp2: fix spindown for PL-3507 and TSB42AA9 firmwares Reported by Tino Keitel: PL-3507 with firmware from Prolific does not spin down the disk on START STOP UNIT with power condition = 0 and start = 0. It does however work with power condition = 2 or 3. Also found while investigating this: DViCO Momobay CX-1 and FX-3A (TI TSB42AA9/A based) become unresponsive after START STOP UNIT with power condition = 0 and start = 0. They stay responsive if power condition is set when stopping the motor. Signed-off-by: Stefan Richter Tested-by: Tino Keitel --- diff --git a/drivers/firewire/fw-sbp2.c b/drivers/firewire/fw-sbp2.c index 227d2e036cd8..bb8830fb0b7c 100644 --- a/drivers/firewire/fw-sbp2.c +++ b/drivers/firewire/fw-sbp2.c @@ -86,6 +86,11 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device " * - delay inquiry * Wait extra SBP2_INQUIRY_DELAY seconds after login before SCSI inquiry. * + * - power condition + * Set the power condition field in the START STOP UNIT commands sent by + * sd_mod on suspend, resume, and shutdown (if manage_start_stop is on). + * Some disks need this to spin down or to resume properly. + * * - override internal blacklist * Instead of adding to the built-in blacklist, use only the workarounds * specified in the module load parameter. @@ -97,6 +102,7 @@ MODULE_PARM_DESC(exclusive_login, "Exclusive login to sbp2 device " #define SBP2_WORKAROUND_FIX_CAPACITY 0x8 #define SBP2_WORKAROUND_DELAY_INQUIRY 0x10 #define SBP2_INQUIRY_DELAY 12 +#define SBP2_WORKAROUND_POWER_CONDITION 0x20 #define SBP2_WORKAROUND_OVERRIDE 0x100 static int sbp2_param_workarounds; @@ -107,6 +113,8 @@ MODULE_PARM_DESC(workarounds, "Work around device bugs (default = 0" ", skip mode page 8 = " __stringify(SBP2_WORKAROUND_MODE_SENSE_8) ", fix capacity = " __stringify(SBP2_WORKAROUND_FIX_CAPACITY) ", delay inquiry = " __stringify(SBP2_WORKAROUND_DELAY_INQUIRY) + ", set power condition in start stop unit = " + __stringify(SBP2_WORKAROUND_POWER_CONDITION) ", override internal blacklist = " __stringify(SBP2_WORKAROUND_OVERRIDE) ", or a combination)"); @@ -310,18 +318,25 @@ static const struct { .firmware_revision = 0x002800, .model = 0x001010, .workarounds = SBP2_WORKAROUND_INQUIRY_36 | - SBP2_WORKAROUND_MODE_SENSE_8, + SBP2_WORKAROUND_MODE_SENSE_8 | + SBP2_WORKAROUND_POWER_CONDITION, }, /* DViCO Momobay FX-3A with TSB42AA9A bridge */ { .firmware_revision = 0x002800, .model = 0x000000, - .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY, + .workarounds = SBP2_WORKAROUND_DELAY_INQUIRY | + SBP2_WORKAROUND_POWER_CONDITION, }, /* Initio bridges, actually only needed for some older ones */ { .firmware_revision = 0x000200, .model = ~0, .workarounds = SBP2_WORKAROUND_INQUIRY_36, }, + /* PL-3507 bridge with Prolific firmware */ { + .firmware_revision = 0x012800, + .model = ~0, + .workarounds = SBP2_WORKAROUND_POWER_CONDITION, + }, /* Symbios bridge */ { .firmware_revision = 0xa0b800, .model = ~0, @@ -1540,6 +1555,9 @@ static int sbp2_scsi_slave_configure(struct scsi_device *sdev) if (lu->tgt->workarounds & SBP2_WORKAROUND_FIX_CAPACITY) sdev->fix_capacity = 1; + if (lu->tgt->workarounds & SBP2_WORKAROUND_POWER_CONDITION) + sdev->start_stop_pwr_cond = 1; + if (lu->tgt->workarounds & SBP2_WORKAROUND_128K_MAX_TRANS) blk_queue_max_sectors(sdev->request_queue, 128 * 1024 / 512);