From: Ian Abbott Date: Tue, 9 Feb 2016 15:17:21 +0000 (+0000) Subject: staging: comedi: comedi.h: add kernel-doc to common enums X-Git-Url: https://git.stricted.de/?a=commitdiff_plain;h=8fb02b29470fec3c0463d740e52f3348a701b7ca;p=GitHub%2FLineageOS%2Fandroid_kernel_motorola_exynos9610.git staging: comedi: comedi.h: add kernel-doc to common enums Add "kernel-doc"-formatted comments to COMEDI's general-purpose `enum` type declarations. Don't bother documenting the low-level driver-specific ones for now. Move the declaration of `enum comedi_counter_status_flags` next to the other general-purpose `enum` types. Signed-off-by: Ian Abbott Signed-off-by: Greg Kroah-Hartman --- diff --git a/drivers/staging/comedi/comedi.h b/drivers/staging/comedi/comedi.h index c157c41a9cc7..9ef0963101da 100644 --- a/drivers/staging/comedi/comedi.h +++ b/drivers/staging/comedi/comedi.h @@ -223,24 +223,91 @@ /* subdevice types */ +/** + * enum comedi_subdevice_type - COMEDI subdevice types + * @COMEDI_SUBD_UNUSED: Unused subdevice. + * @COMEDI_SUBD_AI: Analog input. + * @COMEDI_SUBD_AO: Analog output. + * @COMEDI_SUBD_DI: Digital input. + * @COMEDI_SUBD_DO: Digital output. + * @COMEDI_SUBD_DIO: Digital input/output. + * @COMEDI_SUBD_COUNTER: Counter. + * @COMEDI_SUBD_TIMER: Timer. + * @COMEDI_SUBD_MEMORY: Memory, EEPROM, DPRAM. + * @COMEDI_SUBD_CALIB: Calibration DACs. + * @COMEDI_SUBD_PROC: Processor, DSP. + * @COMEDI_SUBD_SERIAL: Serial I/O. + * @COMEDI_SUBD_PWM: Pulse-Width Modulation output. + */ enum comedi_subdevice_type { - COMEDI_SUBD_UNUSED, /* unused by driver */ - COMEDI_SUBD_AI, /* analog input */ - COMEDI_SUBD_AO, /* analog output */ - COMEDI_SUBD_DI, /* digital input */ - COMEDI_SUBD_DO, /* digital output */ - COMEDI_SUBD_DIO, /* digital input/output */ - COMEDI_SUBD_COUNTER, /* counter */ - COMEDI_SUBD_TIMER, /* timer */ - COMEDI_SUBD_MEMORY, /* memory, EEPROM, DPRAM */ - COMEDI_SUBD_CALIB, /* calibration DACs */ - COMEDI_SUBD_PROC, /* processor, DSP */ - COMEDI_SUBD_SERIAL, /* serial IO */ - COMEDI_SUBD_PWM /* PWM */ + COMEDI_SUBD_UNUSED, + COMEDI_SUBD_AI, + COMEDI_SUBD_AO, + COMEDI_SUBD_DI, + COMEDI_SUBD_DO, + COMEDI_SUBD_DIO, + COMEDI_SUBD_COUNTER, + COMEDI_SUBD_TIMER, + COMEDI_SUBD_MEMORY, + COMEDI_SUBD_CALIB, + COMEDI_SUBD_PROC, + COMEDI_SUBD_SERIAL, + COMEDI_SUBD_PWM }; /* configuration instructions */ +/** + * enum configuration_ids - COMEDI configuration instruction codes + * @INSN_CONFIG_DIO_INPUT: Configure digital I/O as input. + * @INSN_CONFIG_DIO_OUTPUT: Configure digital I/O as output. + * @INSN_CONFIG_DIO_OPENDRAIN: Configure digital I/O as open-drain (or open + * collector) output. + * @INSN_CONFIG_ANALOG_TRIG: Configure analog trigger. + * @INSN_CONFIG_ALT_SOURCE: Configure alternate input source. + * @INSN_CONFIG_DIGITAL_TRIG: Configure digital trigger. + * @INSN_CONFIG_BLOCK_SIZE: Configure block size for DMA transfers. + * @INSN_CONFIG_TIMER_1: Configure divisor for external clock. + * @INSN_CONFIG_FILTER: Configure a filter. + * @INSN_CONFIG_CHANGE_NOTIFY: Configure change notification for digital + * inputs. (New drivers should use + * %INSN_CONFIG_DIGITAL_TRIG instead.) + * @INSN_CONFIG_SERIAL_CLOCK: Configure clock for serial I/O. + * @INSN_CONFIG_BIDIRECTIONAL_DATA: Send and receive byte over serial I/O. + * @INSN_CONFIG_DIO_QUERY: Query direction of digital I/O channel. + * @INSN_CONFIG_PWM_OUTPUT: Configure pulse-width modulator output. + * @INSN_CONFIG_GET_PWM_OUTPUT: Get pulse-width modulator output configuration. + * @INSN_CONFIG_ARM: Arm a subdevice or channel. + * @INSN_CONFIG_DISARM: Disarm a subdevice or channel. + * @INSN_CONFIG_GET_COUNTER_STATUS: Get counter status. + * @INSN_CONFIG_RESET: Reset a subdevice or channel. + * @INSN_CONFIG_GPCT_SINGLE_PULSE_GENERATOR: Configure counter/timer as + * single pulse generator. + * @INSN_CONFIG_GPCT_PULSE_TRAIN_GENERATOR: Configure counter/timer as + * pulse train generator. + * @INSN_CONFIG_GPCT_QUADRATURE_ENCODER: Configure counter as a quadrature + * encoder. + * @INSN_CONFIG_SET_GATE_SRC: Set counter/timer gate source. + * @INSN_CONFIG_GET_GATE_SRC: Get counter/timer gate source. + * @INSN_CONFIG_SET_CLOCK_SRC: Set counter/timer master clock source. + * @INSN_CONFIG_GET_CLOCK_SRC: Get counter/timer master clock source. + * @INSN_CONFIG_SET_OTHER_SRC: Set counter/timer "other" source. + * @INSN_CONFIG_GET_HARDWARE_BUFFER_SIZE: Get size (in bytes) of subdevice's + * on-board FIFOs used during streaming + * input/output. + * @INSN_CONFIG_SET_COUNTER_MODE: Set counter/timer mode. + * @INSN_CONFIG_8254_SET_MODE: (Deprecated) Same as + * %INSN_CONFIG_SET_COUNTER_MODE. + * @INSN_CONFIG_8254_READ_STATUS: Read status of 8254 counter channel. + * @INSN_CONFIG_SET_ROUTING: Set routing for a channel. + * @INSN_CONFIG_GET_ROUTING: Get routing for a channel. + * @INSN_CONFIG_PWM_SET_PERIOD: Set PWM period in nanoseconds. + * @INSN_CONFIG_PWM_GET_PERIOD: Get PWM period in nanoseconds. + * @INSN_CONFIG_GET_PWM_STATUS: Get PWM status. + * @INSN_CONFIG_PWM_SET_H_BRIDGE: Set PWM H bridge duty cycle and polarity for + * a relay simultaneously. + * @INSN_CONFIG_PWM_GET_H_BRIDGE: Get PWM H bridge duty cycle and polarity. + */ enum configuration_ids { INSN_CONFIG_DIO_INPUT = 0, INSN_CONFIG_DIO_OUTPUT = 1, @@ -265,72 +332,76 @@ enum configuration_ids { INSN_CONFIG_DISARM = 32, INSN_CONFIG_GET_COUNTER_STATUS = 33, INSN_CONFIG_RESET = 34, - /* Use CTR as single pulsegenerator */ INSN_CONFIG_GPCT_SINGLE_PULSE_GENERATOR = 1001, - /* Use CTR as pulsetraingenerator */ INSN_CONFIG_GPCT_PULSE_TRAIN_GENERATOR = 1002, - /* Use the counter as encoder */ INSN_CONFIG_GPCT_QUADRATURE_ENCODER = 1003, - INSN_CONFIG_SET_GATE_SRC = 2001, /* Set gate source */ - INSN_CONFIG_GET_GATE_SRC = 2002, /* Get gate source */ - /* Set master clock source */ + INSN_CONFIG_SET_GATE_SRC = 2001, + INSN_CONFIG_GET_GATE_SRC = 2002, INSN_CONFIG_SET_CLOCK_SRC = 2003, - INSN_CONFIG_GET_CLOCK_SRC = 2004, /* Get master clock source */ - INSN_CONFIG_SET_OTHER_SRC = 2005, /* Set other source */ - /* INSN_CONFIG_GET_OTHER_SRC = 2006,*//* Get other source */ - /* Get size in bytes of subdevice's on-board fifos used during - * streaming input/output - */ + INSN_CONFIG_GET_CLOCK_SRC = 2004, + INSN_CONFIG_SET_OTHER_SRC = 2005, INSN_CONFIG_GET_HARDWARE_BUFFER_SIZE = 2006, INSN_CONFIG_SET_COUNTER_MODE = 4097, - /* INSN_CONFIG_8254_SET_MODE is deprecated */ INSN_CONFIG_8254_SET_MODE = INSN_CONFIG_SET_COUNTER_MODE, INSN_CONFIG_8254_READ_STATUS = 4098, INSN_CONFIG_SET_ROUTING = 4099, INSN_CONFIG_GET_ROUTING = 4109, - /* PWM */ - INSN_CONFIG_PWM_SET_PERIOD = 5000, /* sets frequency */ - INSN_CONFIG_PWM_GET_PERIOD = 5001, /* gets frequency */ - INSN_CONFIG_GET_PWM_STATUS = 5002, /* is it running? */ - /* sets H bridge: duty cycle and sign bit for a relay at the - * same time - */ + INSN_CONFIG_PWM_SET_PERIOD = 5000, + INSN_CONFIG_PWM_GET_PERIOD = 5001, + INSN_CONFIG_GET_PWM_STATUS = 5002, INSN_CONFIG_PWM_SET_H_BRIDGE = 5003, - /* gets H bridge data: duty cycle and the sign bit */ INSN_CONFIG_PWM_GET_H_BRIDGE = 5004 }; -/* - * Settings for INSN_CONFIG_DIGITAL_TRIG: - * data[0] = INSN_CONFIG_DIGITAL_TRIG - * data[1] = trigger ID - * data[2] = configuration operation - * data[3] = configuration parameter 1 - * data[4] = configuration parameter 2 - * data[5] = configuration parameter 3 +/** + * enum comedi_digital_trig_op - operations for configuring a digital trigger + * @COMEDI_DIGITAL_TRIG_DISABLE: Return digital trigger to its default, + * inactive, unconfigured state. + * @COMEDI_DIGITAL_TRIG_ENABLE_EDGES: Set rising and/or falling edge inputs + * that each can fire the trigger. + * @COMEDI_DIGITAL_TRIG_ENABLE_LEVELS: Set a combination of high and/or low + * level inputs that can fire the trigger. + * + * These are used with the %INSN_CONFIG_DIGITAL_TRIG configuration instruction. + * The data for the configuration instruction is as follows... + * + * data[%0] = %INSN_CONFIG_DIGITAL_TRIG * - * operation parameter 1 parameter 2 parameter 3 - * --------------------------------- ----------- ----------- ----------- - * COMEDI_DIGITAL_TRIG_DISABLE - * COMEDI_DIGITAL_TRIG_ENABLE_EDGES left-shift rising-edges falling-edges - * COMEDI_DIGITAL_TRIG_ENABLE_LEVELS left-shift high-levels low-levels + * data[%1] = trigger ID * - * COMEDI_DIGITAL_TRIG_DISABLE returns the trigger to its default, inactive, - * unconfigured state. + * data[%2] = configuration operation * - * COMEDI_DIGITAL_TRIG_ENABLE_EDGES sets the rising and/or falling edge inputs - * that each can fire the trigger. + * data[%3] = configuration parameter 1 * - * COMEDI_DIGITAL_TRIG_ENABLE_LEVELS sets a combination of high and/or low - * level inputs that can fire the trigger. + * data[%4] = configuration parameter 2 * - * "left-shift" is useful if the trigger has more than 32 inputs to specify the - * first input for this configuration. + * data[%5] = configuration parameter 3 * - * Some sequences of INSN_CONFIG_DIGITAL_TRIG instructions may have a (partly) + * The trigger ID (data[%1]) is used to differentiate multiple digital triggers + * belonging to the same subdevice. The configuration operation (data[%2]) is + * one of the enum comedi_digital_trig_op values. The configuration + * parameters (data[%3], data[%4], and data[%5]) depend on the operation; they + * are not used with %COMEDI_DIGITAL_TRIG_DISABLE. + * + * For %COMEDI_DIGITAL_TRIG_ENABLE_EDGES and %COMEDI_DIGITAL_TRIG_ENABLE_LEVELS, + * configuration parameter 1 (data[%3]) contains a "left-shift" value that + * specifies the input corresponding to bit 0 of configuration parameters 2 + * and 3. This is useful if the trigger has more than 32 inputs. + * + * For %COMEDI_DIGITAL_TRIG_ENABLE_EDGES, configuration parameter 2 (data[%4]) + * specifies which of up to 32 inputs have rising-edge sensitivity, and + * configuration parameter 3 (data[%5]) specifies which of up to 32 inputs + * have falling-edge sensitivity that can fire the trigger. + * + * For %COMEDI_DIGITAL_TRIG_ENABLE_LEVELS, configuration parameter 2 (data[%4]) + * specifies which of up to 32 inputs must be at a high level, and + * configuration parameter 3 (data[%5]) specifies which of up to 32 inputs + * must be at a low level for the trigger to fire. + * + * Some sequences of %INSN_CONFIG_DIGITAL_TRIG instructions may have a (partly) * accumulative effect, depending on the low-level driver. This is useful - * when setting up a trigger that has more than 32 inputs or has a combination - * of edge and level triggered inputs. + * when setting up a trigger that has more than 32 inputs, or has a combination + * of edge- and level-triggered inputs. */ enum comedi_digital_trig_op { COMEDI_DIGITAL_TRIG_DISABLE = 0, @@ -338,18 +409,49 @@ enum comedi_digital_trig_op { COMEDI_DIGITAL_TRIG_ENABLE_LEVELS = 2 }; +/** + * enum comedi_io_direction - COMEDI I/O directions + * @COMEDI_INPUT: Input. + * @COMEDI_OUTPUT: Output. + * @COMEDI_OPENDRAIN: Open-drain (or open-collector) output. + * + * These are used by the %INSN_CONFIG_DIO_QUERY configuration instruction to + * report a direction. They may also be used in other places where a direction + * needs to be specified. + */ enum comedi_io_direction { COMEDI_INPUT = 0, COMEDI_OUTPUT = 1, COMEDI_OPENDRAIN = 2 }; +/** + * enum comedi_support_level - support level for a COMEDI feature + * @COMEDI_UNKNOWN_SUPPORT: Unspecified support for feature. + * @COMEDI_SUPPORTED: Feature is supported. + * @COMEDI_UNSUPPORTED: Feature is unsupported. + */ enum comedi_support_level { COMEDI_UNKNOWN_SUPPORT = 0, COMEDI_SUPPORTED, COMEDI_UNSUPPORTED }; +/** + * enum comedi_counter_status_flags - counter status bits + * @COMEDI_COUNTER_ARMED: Counter is armed. + * @COMEDI_COUNTER_COUNTING: Counter is counting. + * @COMEDI_COUNTER_TERMINAL_COUNT: Counter reached terminal count. + * + * These bitwise values are used by the %INSN_CONFIG_GET_COUNTER_STATUS + * configuration instruction to report the status of a counter. + */ +enum comedi_counter_status_flags { + COMEDI_COUNTER_ARMED = 0x1, + COMEDI_COUNTER_COUNTING = 0x2, + COMEDI_COUNTER_TERMINAL_COUNT = 0x4, +}; + /* ioctls */ #define CIO 'd' @@ -849,13 +951,6 @@ enum ni_660x_pfi_routing { #define NI_EXT_PFI(x) (NI_USUAL_PFI_SELECT(x) - 1) #define NI_EXT_RTSI(x) (NI_USUAL_RTSI_SELECT(x) - 1) -/* status bits for INSN_CONFIG_GET_COUNTER_STATUS */ -enum comedi_counter_status_flags { - COMEDI_COUNTER_ARMED = 0x1, - COMEDI_COUNTER_COUNTING = 0x2, - COMEDI_COUNTER_TERMINAL_COUNT = 0x4, -}; - /* * Clock sources for CDIO subdevice on NI m-series boards. Used as the * scan_begin_arg for a comedi_command. These sources may also be bitwise-or'd