From: Philipp Zabel
Date: Fri, 10 Jul 2015 13:37:44 +0000 (-0300)
Subject: [media] coda: reset CODA960 hardware after sequence end
X-Git-Url: https://git.stricted.de/?a=commitdiff_plain;h=68aa7ee15cd683006ec1ac91ad60c019bf62d978;p=GitHub%2Fmoto-9609%2Fandroid_kernel_motorola_exynos9610.git
[media] coda: reset CODA960 hardware after sequence end
On i.MX6, sometimes after decoding a stream, encoding will produce macroblock
errors caused by missing 8-byte sequences in the output stream. Until the cause
for this is found, reset the hardware after sequence end, which seems to help.
Signed-off-by: Philipp Zabel
Signed-off-by: Hans Verkuil
Signed-off-by: Mauro Carvalho Chehab
---
diff --git a/drivers/media/platform/coda/coda-bit.c b/drivers/media/platform/coda/coda-bit.c
index 25910ccd2da0..bcb9911d5e3f 100644
--- a/drivers/media/platform/coda/coda-bit.c
+++ b/drivers/media/platform/coda/coda-bit.c
@@ -1347,6 +1347,14 @@ static void coda_seq_end_work(struct work_struct *work)
"CODA_COMMAND_SEQ_END failed\n");
}
+ /*
+ * FIXME: Sometimes h.264 encoding fails with 8-byte sequences missing
+ * from the output stream after the h.264 decoder has run. Resetting the
+ * hardware after the decoder has finished seems to help.
+ */
+ if (dev->devtype->product == CODA_960)
+ coda_hw_reset(ctx);
+
kfifo_init(&ctx->bitstream_fifo,
ctx->bitstream.vaddr, ctx->bitstream.size);