From: Wei Ni Date: Wed, 11 May 2016 10:20:25 +0000 (+0800) Subject: arm64: tegra: set critical trips for Tegra210 X-Git-Url: https://git.stricted.de/?a=commitdiff_plain;h=5e03f663ca6f3cddb6512df07233c71645fb04a7;p=GitHub%2FLineageOS%2Fandroid_kernel_motorola_exynos9610.git arm64: tegra: set critical trips for Tegra210 Set general "critical" trip temperatures for cpu, gpu, mem and pllx thermal zones on Tegra210, these trips can trigger shut down or reset. Signed-off-by: Wei Ni Signed-off-by: Zhang Rui --- diff --git a/arch/arm64/boot/dts/nvidia/tegra210.dtsi b/arch/arm64/boot/dts/nvidia/tegra210.dtsi index ec59e9e4714f..604c99909c8e 100644 --- a/arch/arm64/boot/dts/nvidia/tegra210.dtsi +++ b/arch/arm64/boot/dts/nvidia/tegra210.dtsi @@ -1115,6 +1115,21 @@ thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>; + + trips { + cpu-shutdown-trip { + temperature = <102500>; + hysteresis = <0>; + type = "critical"; + }; + }; + + cooling-maps { + /* + * There are currently no cooling maps, + * because there are no cooling devices. + */ + }; }; mem { polling-delay-passive = <0>; @@ -1122,6 +1137,21 @@ thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_MEM>; + + trips { + mem-shutdown-trip { + temperature = <103000>; + hysteresis = <0>; + type = "critical"; + }; + }; + + cooling-maps { + /* + * There are currently no cooling maps, + * because there are no cooling devices. + */ + }; }; gpu { polling-delay-passive = <1000>; @@ -1129,6 +1159,21 @@ thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_GPU>; + + trips { + gpu-shutdown-trip { + temperature = <103000>; + hysteresis = <0>; + type = "critical"; + }; + }; + + cooling-maps { + /* + * There are currently no cooling maps, + * because there are no cooling devices. + */ + }; }; pllx { polling-delay-passive = <0>; @@ -1136,6 +1181,21 @@ thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_PLLX>; + + trips { + pllx-shutdown-trip { + temperature = <103000>; + hysteresis = <0>; + type = "critical"; + }; + }; + + cooling-maps { + /* + * There are currently no cooling maps, + * because there are no cooling devices. + */ + }; }; }; };