From: Simon Guo Date: Thu, 29 Jan 2015 05:33:17 +0000 (+0800) Subject: STAGING: Fix pcl818.c coding style issue: code indent should use tabs where possible X-Git-Url: https://git.stricted.de/?a=commitdiff_plain;h=25ef8072fbea1843c29c24cf82e6913c504db55c;p=GitHub%2FLineageOS%2FG12%2Fandroid_kernel_amlogic_linux-4.9.git STAGING: Fix pcl818.c coding style issue: code indent should use tabs where possible Correct one coding style problem(detected by checkpatch.pl) in pcl818.c. - code indent should use tabs where possible It is fixed by reformatting the comment block to usual comment style. And with the reformatting, following coding style problem is also fixed: - please, no space before tabs Signed-off-by: Simon Guo Reviewed-by: Ian Abbott Signed-off-by: Greg Kroah-Hartman --- diff --git a/drivers/staging/comedi/drivers/pcl818.c b/drivers/staging/comedi/drivers/pcl818.c index a10ce41067ee..47a2f7bb22f4 100644 --- a/drivers/staging/comedi/drivers/pcl818.c +++ b/drivers/staging/comedi/drivers/pcl818.c @@ -1,102 +1,95 @@ /* - comedi/drivers/pcl818.c - - Author: Michal Dobes - - hardware driver for Advantech cards: - card: PCL-818L, PCL-818H, PCL-818HD, PCL-818HG, PCL-818, PCL-718 - driver: pcl818l, pcl818h, pcl818hd, pcl818hg, pcl818, pcl718 -*/ -/* -Driver: pcl818 -Description: Advantech PCL-818 cards, PCL-718 -Author: Michal Dobes -Devices: [Advantech] PCL-818L (pcl818l), PCL-818H (pcl818h), - PCL-818HD (pcl818hd), PCL-818HG (pcl818hg), PCL-818 (pcl818), - PCL-718 (pcl718) -Status: works - -All cards have 16 SE/8 DIFF ADCs, one or two DACs, 16 DI and 16 DO. -Differences are only at maximal sample speed, range list and FIFO -support. -The driver support AI mode 0, 1, 3 other subdevices (AO, DI, DO) support -only mode 0. If DMA/FIFO/INT are disabled then AI support only mode 0. -PCL-818HD and PCL-818HG support 1kword FIFO. Driver support this FIFO -but this code is untested. -A word or two about DMA. Driver support DMA operations at two ways: -1) DMA uses two buffers and after one is filled then is generated - INT and DMA restart with second buffer. With this mode I'm unable run - more that 80Ksamples/secs without data dropouts on K6/233. -2) DMA uses one buffer and run in autoinit mode and the data are - from DMA buffer moved on the fly with 2kHz interrupts from RTC. - This mode is used if the interrupt 8 is available for allocation. - If not, then first DMA mode is used. With this I can run at - full speed one card (100ksamples/secs) or two cards with - 60ksamples/secs each (more is problem on account of ISA limitations). - To use this mode you must have compiled kernel with disabled - "Enhanced Real Time Clock Support". - Maybe you can have problems if you use xntpd or similar. - If you've data dropouts with DMA mode 2 then: - a) disable IDE DMA - b) switch text mode console to fb. - - Options for PCL-818L: - [0] - IO Base - [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) - [2] - DMA (0=disable, 1, 3) - [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 - [4] - 0, 5=A/D input -5V.. +5V - 1, 10=A/D input -10V..+10V - [5] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) - 2 =D/A output unknown (external reference) - - Options for PCL-818, PCL-818H: - [0] - IO Base - [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) - [2] - DMA (0=disable, 1, 3) - [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 - [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) - 2 =D/A output unknown (external reference) - - Options for PCL-818HD, PCL-818HG: - [0] - IO Base - [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) - [2] - DMA/FIFO (-1=use FIFO, 0=disable both FIFO and DMA, - 1=use DMA ch 1, 3=use DMA ch 3) - [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 - [4] - 0, 5=D/A output 0-5V (internal reference -5V) - 1, 10=D/A output 0-10V (internal reference -10V) - 2 =D/A output unknown (external reference) - - Options for PCL-718: - [0] - IO Base - [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) - [2] - DMA (0=disable, 1, 3) - [3] - 0, 10=10MHz clock for 8254 - 1= 1MHz clock for 8254 - [4] - 0=A/D Range is +/-10V - 1= +/-5V - 2= +/-2.5V - 3= +/-1V - 4= +/-0.5V - 5= user defined bipolar - 6= 0-10V - 7= 0-5V - 8= 0-2V - 9= 0-1V - 10= user defined unipolar - [5] - 0, 5=D/A outputs 0-5V (internal reference -5V) - 1, 10=D/A outputs 0-10V (internal reference -10V) - 2=D/A outputs unknown (external reference) - [6] - 0, 60=max 60kHz A/D sampling - 1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) - -*/ + * comedi/drivers/pcl818.c + * + * Driver: pcl818 + * Description: Advantech PCL-818 cards, PCL-718 + * Author: Michal Dobes + * Devices: [Advantech] PCL-818L (pcl818l), PCL-818H (pcl818h), + * PCL-818HD (pcl818hd), PCL-818HG (pcl818hg), PCL-818 (pcl818), + * PCL-718 (pcl718) + * Status: works + * + * All cards have 16 SE/8 DIFF ADCs, one or two DACs, 16 DI and 16 DO. + * Differences are only at maximal sample speed, range list and FIFO + * support. + * The driver support AI mode 0, 1, 3 other subdevices (AO, DI, DO) support + * only mode 0. If DMA/FIFO/INT are disabled then AI support only mode 0. + * PCL-818HD and PCL-818HG support 1kword FIFO. Driver support this FIFO + * but this code is untested. + * A word or two about DMA. Driver support DMA operations at two ways: + * 1) DMA uses two buffers and after one is filled then is generated + * INT and DMA restart with second buffer. With this mode I'm unable run + * more that 80Ksamples/secs without data dropouts on K6/233. + * 2) DMA uses one buffer and run in autoinit mode and the data are + * from DMA buffer moved on the fly with 2kHz interrupts from RTC. + * This mode is used if the interrupt 8 is available for allocation. + * If not, then first DMA mode is used. With this I can run at + * full speed one card (100ksamples/secs) or two cards with + * 60ksamples/secs each (more is problem on account of ISA limitations). + * To use this mode you must have compiled kernel with disabled + * "Enhanced Real Time Clock Support". + * Maybe you can have problems if you use xntpd or similar. + * If you've data dropouts with DMA mode 2 then: + * a) disable IDE DMA + * b) switch text mode console to fb. + * + * Options for PCL-818L: + * [0] - IO Base + * [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) + * [2] - DMA (0=disable, 1, 3) + * [3] - 0, 10=10MHz clock for 8254 + * 1= 1MHz clock for 8254 + * [4] - 0, 5=A/D input -5V.. +5V + * 1, 10=A/D input -10V..+10V + * [5] - 0, 5=D/A output 0-5V (internal reference -5V) + * 1, 10=D/A output 0-10V (internal reference -10V) + * 2 =D/A output unknown (external reference) + * + * Options for PCL-818, PCL-818H: + * [0] - IO Base + * [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) + * [2] - DMA (0=disable, 1, 3) + * [3] - 0, 10=10MHz clock for 8254 + * 1= 1MHz clock for 8254 + * [4] - 0, 5=D/A output 0-5V (internal reference -5V) + * 1, 10=D/A output 0-10V (internal reference -10V) + * 2 =D/A output unknown (external reference) + * + * Options for PCL-818HD, PCL-818HG: + * [0] - IO Base + * [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) + * [2] - DMA/FIFO (-1=use FIFO, 0=disable both FIFO and DMA, + * 1=use DMA ch 1, 3=use DMA ch 3) + * [3] - 0, 10=10MHz clock for 8254 + * 1= 1MHz clock for 8254 + * [4] - 0, 5=D/A output 0-5V (internal reference -5V) + * 1, 10=D/A output 0-10V (internal reference -10V) + * 2 =D/A output unknown (external reference) + * + * Options for PCL-718: + * [0] - IO Base + * [1] - IRQ (0=disable, 2, 3, 4, 5, 6, 7) + * [2] - DMA (0=disable, 1, 3) + * [3] - 0, 10=10MHz clock for 8254 + * 1= 1MHz clock for 8254 + * [4] - 0=A/D Range is +/-10V + * 1= +/-5V + * 2= +/-2.5V + * 3= +/-1V + * 4= +/-0.5V + * 5= user defined bipolar + * 6= 0-10V + * 7= 0-5V + * 8= 0-2V + * 9= 0-1V + * 10= user defined unipolar + * [5] - 0, 5=D/A outputs 0-5V (internal reference -5V) + * 1, 10=D/A outputs 0-10V (internal reference -10V) + * 2=D/A outputs unknown (external reference) + * [6] - 0, 60=max 60kHz A/D sampling + * 1,100=max 100kHz A/D sampling (PCL-718 with Option 001 installed) + * + */ #include #include