We've been seeing hard-to-trigger psi crashes when running inside VM
instances:
divide error: 0000 [#1] SMP PTI
Modules linked in: [...]
CPU: 0 PID: 212 Comm: kworker/0:2 Not tainted 4.16.18-119_fbk9_3817_gfe944c98d695 #119
Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS 0.0.0 02/06/2015
Workqueue: events psi_clock
RIP: 0010:psi_update_stats+0x270/0x490
RSP: 0018:
ffffc90001117e10 EFLAGS:
00010246
RAX:
0000000000000000 RBX:
0000000000000000 RCX:
ffff8800a35a13f8
RDX:
0000000000000000 RSI:
ffff8800a35a1340 RDI:
0000000000000000
RBP:
0000000000000658 R08:
ffff8800a35a1470 R09:
0000000000000000
R10:
0000000000000000 R11:
0000000000000000 R12:
0000000000000000
R13:
0000000000000000 R14:
0000000000000000 R15:
00000000000f8502
FS:
0000000000000000(0000) GS:
ffff88023fc00000(0000) knlGS:
0000000000000000
CS: 0010 DS: 0000 ES: 0000 CR0:
0000000080050033
CR2:
00007fbe370fa000 CR3:
00000000b1e3a000 CR4:
00000000000006f0
DR0:
0000000000000000 DR1:
0000000000000000 DR2:
0000000000000000
DR3:
0000000000000000 DR6:
00000000fffe0ff0 DR7:
0000000000000400
Call Trace:
psi_clock+0x12/0x50
process_one_work+0x1e0/0x390
worker_thread+0x2b/0x3c0
? rescuer_thread+0x330/0x330
kthread+0x113/0x130
? kthread_create_worker_on_cpu+0x40/0x40
? SyS_exit_group+0x10/0x10
ret_from_fork+0x35/0x40
Code: 48 0f 47 c7 48 01 c2 45 85 e4 48 89 16 0f 85 e6 00 00 00 4c 8b 49 10 4c 8b 51 08 49 69 d9 f2 07 00 00 48 6b c0 64 4c 8b 29 31 d2 <48> f7 f7 49 69 d5 8d 06 00 00 48 89 c5 4c 69 f0 00 98 0b 00 48
The Code-line points to `period` being 0 inside update_stats(), and we
divide by that when calculating that period's pressure percentage.
The elapsed period should never be 0. The reason this can happen is due
to an off-by-one in the idle time / missing period calculation combined
with a coarse sched_clock() in the virtual machine.
The target time for aggregation is advanced into the future on a fixed
grid to prevent clock drift. So when an aggregation runs after some idle
period, we can not just set it to "now + psi_period", but have to
calculate the downtime and advance the target time relative to itself.
However, if the aggregator was disabled exactly one psi_period (ns), we
drop one idle period in the calculation due to a > when we should do >=.
In that case, next_update will be advanced from 'now - psi_period' to
'now' when it should be moved to 'now + psi_period'. The run finishes
with last_update == next_update == sched_clock().
With hardware clocks, this exact nanosecond match isn't l(CR) in the
first place; but if it does happen, the clock will still have moved on and
the period non-zero by the time the worker runs. A pointlessly short
period, but besides the extra work, no harm no foul. However, a slow
sched_clock() l(CR) we have on VMs might not have advanced either by the
time the worker runs again. And when we calculate the elapsed period, the
result, our pressure divisor, will be 0. Ouch.
Fix this by correctly handling the situation when the elapsed time between
aggregation runs is precisely two periods, and advance the expiration
timestamp correctly to period into the future.
Link: http://lkml.kernel.org/r/20190214193157.15788-1-hannes@cmpxchg.org
Signed-off-by: Johannes Weiner <hannes@cmpxchg.org>
Reported-by: Ćukasz Siudut <lsiudut@fb.com
Reviewed-by: Andrew Morton <akpm@linux-foundation.org>
Cc: Peter Zijlstra <peterz@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
(cherry picked from commit
4e37504d1c49eec6434d0cc97278d2b51c9e8763)
Bug:
127712811
Test: lmkd in PSI mode
Change-Id: I40917c84354f9f32259c6703f00b6b1d21f45f02
Signed-off-by: Suren Baghdasaryan <surenb@google.com>