Setting the set_voltage_time_sel callback to the standard function
regulator_set_voltage_time_sel enables the regulator to actually honor
ramp-delays when during regulator_set_voltage calls.
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Signed-off-by: Mark Brown <broonie@kernel.org>
static struct regulator_ops fan53555_regulator_ops = {
.set_voltage_sel = regulator_set_voltage_sel_regmap,
.get_voltage_sel = regulator_get_voltage_sel_regmap,
+ .set_voltage_time_sel = regulator_set_voltage_time_sel,
.map_voltage = regulator_map_voltage_linear,
.list_voltage = regulator_list_voltage_linear,
.set_suspend_voltage = fan53555_set_suspend_voltage,