The zfcp_scsi_queuecommand was not acting according to the standard
when the respective unit was not available. In this case an -EBUSY was
returned, which is not valid in itself, and in addition scsi_done
was called. This combination is not allowed and was leading to a
double finish of the request and therefor double decrement of the
host_busy counter.
Signed-off-by: Swen Schillig <swen@vnet.ibm.com>
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
ret = zfcp_fsf_send_fcp_command_task(adapter, unit, scpnt, 0,
ZFCP_REQ_AUTO_CLEANUP);
if (unlikely(ret == -EBUSY))
- zfcp_scsi_command_fail(scpnt, DID_NO_CONNECT);
+ return SCSI_MLQUEUE_DEVICE_BUSY;
else if (unlikely(ret < 0))
return SCSI_MLQUEUE_HOST_BUSY;