The test in mlx4_load_one() to remove MLX4_FLAG_MSI_X expects mlx4_NOP() to
fail with -EBUSY. It is also necessary to avoid the reset since the device
is not fully reinitialized before calling mlx4_start_hca() a second time.
Note that this will also affect mlx4_test_interrupts(), the only other user
of MLX4_CMD_NOP.
Fixes:
f5aef5a ("net/mlx4_core: Activate reset flow upon fatal command cases")
Signed-off-by: Benjamin Poirier <bpoirier@suse.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
msecs_to_jiffies(timeout))) {
mlx4_warn(dev, "command 0x%x timed out (go bit not cleared)\n",
op);
- err = -EIO;
- goto out_reset;
+ if (op == MLX4_CMD_NOP) {
+ err = -EBUSY;
+ goto out;
+ } else {
+ err = -EIO;
+ goto out_reset;
+ }
}
err = context->result;