In some Power7 platforms, when using VIOS (Virtual I/O Server), we
need to wait longer for control packets to finish transfer during
initialization.
Without this change, initialization may fail prematurely.
Signed-off-by: Wen Xiong <wenxiong@us.ibm.com>
Signed-off-by: Andre Detsch <adetsch@br.ibm.com>
Acked-by: Divy Le Ray <divy@chelsio.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
static int await_mgmt_replies(struct adapter *adap, unsigned long init_cnt,
unsigned long n)
{
- int attempts = 5;
+ int attempts = 10;
while (adap->sge.qs[0].rspq.offload_pkts < init_cnt + n) {
if (!--attempts)