This flag is currently never cleared, which can in rare cases
trigger a warn-on if it is still set but the block isn't
InSync.
So clear it when it isn't need, which includes if the replacement
device has failed.
Signed-off-by: NeilBrown <neilb@suse.com>
&first_bad, &bad_sectors))
set_bit(R5_ReadRepl, &dev->flags);
else {
- if (rdev)
+ if (rdev && !test_bit(Faulty, &rdev->flags))
set_bit(R5_NeedReplace, &dev->flags);
+ else
+ clear_bit(R5_NeedReplace, &dev->flags);
rdev = rcu_dereference(conf->disks[i].rdev);
clear_bit(R5_ReadRepl, &dev->flags);
}