u32 temp;
u16 now = ohci_readl(ohci, &ohci->regs->fmnumber);
u16 reset_done = now + PORT_RESET_MSEC;
+ int limit_1 = DIV_ROUND_UP(PORT_RESET_MSEC, PORT_RESET_HW_MSEC);
/* build a "continuous enough" reset signal, with up to
* 3msec gap between pulses. scheduler HZ==100 must work;
* this might need to be deadline-scheduled.
*/
do {
+ int limit_2;
+
/* spin until any current reset finishes */
- for (;;) {
+ limit_2 = PORT_RESET_HW_MSEC * 2;
+ while (--limit_2 >= 0) {
temp = ohci_readl (ohci, portstat);
/* handle e.g. CardBus eject */
if (temp == ~(u32)0)
udelay (500);
}
+ /* timeout (a hardware error) has been observed when
+ * EHCI sets CF while this driver is resetting a port;
+ * presumably other disconnect paths might do it too.
+ */
+ if (limit_2 < 0) {
+ ohci_dbg(ohci,
+ "port[%d] reset timeout, stat %08x\n",
+ port, temp);
+ break;
+ }
+
if (!(temp & RH_PS_CCS))
break;
if (temp & RH_PS_PRSC)
ohci_writel (ohci, RH_PS_PRS, portstat);
msleep(PORT_RESET_HW_MSEC);
now = ohci_readl(ohci, &ohci->regs->fmnumber);
- } while (tick_before(now, reset_done));
- /* caller synchronizes using PRSC */
+ } while (tick_before(now, reset_done) && --limit_1 >= 0);
+
+ /* caller synchronizes using PRSC ... and handles PRS
+ * still being set when this returns.
+ */
return 0;
}