IB/ipath: Fix UC receive completion opcode for RDMA WRITE with immediate
authorRalph Campbell <ralph.campbell@qlogic.com>
Thu, 15 May 2008 23:37:25 +0000 (16:37 -0700)
committerRoland Dreier <rolandd@cisco.com>
Thu, 15 May 2008 23:37:25 +0000 (16:37 -0700)
When I fixed the RC receive completion opcode in 2bfc8e9e ("IB/ipath:
Return the correct opcode for RDMA WRITE with immediate"), I forgot to
fix UC, which had the same problem for RDMA write with immediate
returning the wrong opcode.

Signed-off-by: Ralph Campbell <ralph.campbell@qlogic.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
drivers/infiniband/hw/ipath/ipath_uc.c

index 7fd18e833907dda4ae8a117c3ce6e145a57c0a43..0596ec16fcbd2bfd2b4f1b23bfa45d23b5f86156 100644 (file)
@@ -407,12 +407,11 @@ void ipath_uc_rcv(struct ipath_ibdev *dev, struct ipath_ib_header *hdr,
                        dev->n_pkt_drops++;
                        goto done;
                }
-               /* XXX Need to free SGEs */
+               wc.opcode = IB_WC_RECV;
        last_imm:
                ipath_copy_sge(&qp->r_sge, data, tlen);
                wc.wr_id = qp->r_wr_id;
                wc.status = IB_WC_SUCCESS;
-               wc.opcode = IB_WC_RECV;
                wc.qp = &qp->ibqp;
                wc.src_qp = qp->remote_qpn;
                wc.slid = qp->remote_ah_attr.dlid;
@@ -514,6 +513,7 @@ void ipath_uc_rcv(struct ipath_ibdev *dev, struct ipath_ib_header *hdr,
                        goto done;
                }
                wc.byte_len = qp->r_len;
+               wc.opcode = IB_WC_RECV_RDMA_WITH_IMM;
                goto last_imm;
 
        case OP(RDMA_WRITE_LAST):