Instead of silent acceptance of unsupported requested configuration
for PWM period and setting the boundary supported value, return
-ERANGE to a caller.
Duty period value equal to 0 or period is still accepted to allow
configuration by PWM sysfs interface, when it is set to 0 by default.
For reference this is a list of restrictions on period_ns == 1/freq:
| PWM parent clock | parent clock divisor | max freq | min freq |
+------------------+----------------------+----------+----------+
| HCLK == 13 MHz | 1 (min) | 50.7 KHz | 198.3 Hz |
| HCLK == 13 MHz | 15 (max) | 3.38 KHz | 13.22 Hz |
| RTC == 32.7 KHz | 1 (min) | 128 Hz | 0.5 Hz |
| RTC == 32.7 KHz | 15 (max) | 8.533 Hz | 0.033 Hz |
Note that PWM sysfs interface does not support setting of period more
than NSEC_PER_SEC / MAX_INT32 ~ 2 seconds, however this PWM controller
supports a period up to 30 seconds.
Signed-off-by: Vladimir Zapolskiy <vz@mleia.com>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
/* The highest acceptable divisor is 256, which is represented by 0 */
period_cycles = div64_u64(c * period_ns,
(unsigned long long)NSEC_PER_SEC * 256);
- if (!period_cycles)
- period_cycles = 1;
- if (period_cycles > 255)
+ if (!period_cycles || period_cycles > 256)
+ return -ERANGE;
+ if (period_cycles == 256)
period_cycles = 0;
/* Compute 256 x #duty/period value and care for corner cases */