rtc: interface: Validate alarm-time before handling rollover
authorVaibhav Jain <vaibhav@linux.vnet.ibm.com>
Fri, 19 May 2017 16:48:55 +0000 (22:18 +0530)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 13 Apr 2018 17:48:14 +0000 (19:48 +0200)
[ Upstream commit da96aea0ed177105cb13ee83b328f6c61e061d3f ]

In function __rtc_read_alarm() its possible for an alarm time-stamp to
be invalid even after replacing missing components with current
time-stamp. The condition 'alarm->time.tm_year < 70' will trigger this
case and will cause the call to 'rtc_tm_to_time64(&alarm->time)'
return a negative value for variable t_alm.

While handling alarm rollover this negative t_alm (assumed to seconds
offset from '1970-01-01 00:00:00') is converted back to rtc_time via
rtc_time64_to_tm() which results in this error log with seemingly
garbage values:

"rtc rtc0: invalid alarm value: -2-1--1041528741
2005511117:71582844:32"

This error was generated when the rtc driver (rtc-opal in this case)
returned an alarm time-stamp of '00-00-00 00:00:00' to indicate that
the alarm is disabled. Though I have submitted a separate fix for the
rtc-opal driver, this issue may potentially impact other
existing/future rtc drivers.

To fix this issue the patch validates the alarm time-stamp just after
filling up the missing datetime components and if rtc_valid_tm() still
reports it to be invalid then bails out of the function without
handling the rollover.

Reported-by: Steve Best <sbest@redhat.com>
Signed-off-by: Vaibhav Jain <vaibhav@linux.vnet.ibm.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/rtc/interface.c

index 6ebd42aad291f3c20f7a9c412982208cb219b12b..25cf3069e2e73c9516694ce65645be370a317723 100644 (file)
@@ -227,6 +227,13 @@ int __rtc_read_alarm(struct rtc_device *rtc, struct rtc_wkalrm *alarm)
                        missing = year;
        }
 
+       /* Can't proceed if alarm is still invalid after replacing
+        * missing fields.
+        */
+       err = rtc_valid_tm(&alarm->time);
+       if (err)
+               goto done;
+
        /* with luck, no rollover is needed */
        t_now = rtc_tm_to_time64(&now);
        t_alm = rtc_tm_to_time64(&alarm->time);
@@ -278,9 +285,9 @@ int __rtc_read_alarm(struct rtc_device *rtc, struct rtc_wkalrm *alarm)
                dev_warn(&rtc->dev, "alarm rollover not handled\n");
        }
 
-done:
        err = rtc_valid_tm(&alarm->time);
 
+done:
        if (err) {
                dev_warn(&rtc->dev, "invalid alarm value: %d-%d-%d %d:%d:%d\n",
                        alarm->time.tm_year + 1900, alarm->time.tm_mon + 1,