ep93xx: get_uart_rate() uses the constants EP93XX_SYSCON_CLOCK_CONTROL
and EP93XX_SYSCON_CLOCK_UARTBAUD, which no longer exist. Use
EP93XX_SYSCON_PWRCNT and EP93XX_SYSCON_PWRCNT_UARTBAUD instead
Signed-off-by: Matthias Kaehlcke <matthias@kaehlcke.net>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
{
u32 value;
- value = __raw_readl(EP93XX_SYSCON_CLOCK_CONTROL);
- if (value & EP93XX_SYSCON_CLOCK_UARTBAUD)
+ value = __raw_readl(EP93XX_SYSCON_PWRCNT);
+ if (value & EP93XX_SYSCON_PWRCNT_UARTBAUD)
return EP93XX_EXT_CLK_RATE;
else
return EP93XX_EXT_CLK_RATE / 2;