u16 status[PB_NUM_STATUS_REG];
+ bool has_status_word; /* device uses STATUS_WORD register */
int (*read_status)(struct i2c_client *client, int page);
u8 currpage;
const struct pmbus_sensor_attr *attr)
{
struct pmbus_sensor *base;
+ bool upper = !!(attr->gbit & 0xff00); /* need to check STATUS_WORD */
int ret;
if (attr->label) {
/*
* Add generic alarm attribute only if there are no individual
* alarm attributes, if there is a global alarm bit, and if
- * the generic status register for this page is accessible.
+ * the generic status register (word or byte, depending on
+ * which global bit is set) for this page is accessible.
*/
if (!ret && attr->gbit &&
+ (!upper || (upper && data->has_status_word)) &&
pmbus_check_status_register(client, page)) {
ret = pmbus_add_boolean(data, name, "alarm", index,
NULL, NULL,
.func = PMBUS_HAVE_IIN,
.sfunc = PMBUS_HAVE_STATUS_INPUT,
.sbase = PB_STATUS_INPUT_BASE,
+ .gbit = PB_STATUS_INPUT,
.limit = iin_limit_attrs,
.nlimit = ARRAY_SIZE(iin_limit_attrs),
}, {
.func = PMBUS_HAVE_PIN,
.sfunc = PMBUS_HAVE_STATUS_INPUT,
.sbase = PB_STATUS_INPUT_BASE,
+ .gbit = PB_STATUS_INPUT,
.limit = pin_limit_attrs,
.nlimit = ARRAY_SIZE(pin_limit_attrs),
}, {
dev_err(dev, "PMBus status register not found\n");
return -ENODEV;
}
+ } else {
+ data->has_status_word = true;
}
/* Enable PEC if the controller supports it */