The shunt voltage and current registers are signed 16-bit values so
handle them as such.
Signed-off-by: Joe Schaack <jschaack@xes-inc.com>
Reviewed-by: Aaron Sierra <asierra@xes-inc.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
case INA209_SHUNT_VOLTAGE_POS_WARN:
case INA209_SHUNT_VOLTAGE_NEG_WARN:
/* LSB=10 uV. Convert to mV. */
- return DIV_ROUND_CLOSEST(val, 100);
+ return DIV_ROUND_CLOSEST((s16)val, 100);
case INA209_BUS_VOLTAGE:
case INA209_BUS_VOLTAGE_MAX_PEAK:
case INA209_CURRENT:
/* LSB=1 mA (selected). Is in mA */
- return val;
+ return (s16)val;
}
/* programmer goofed */