Variable mode in method wacom_show_remote_mode() is defined as u8, thus
statement (mode >= 0) is always true and should be removed, simplifying
the logic.
Signed-off-by: Christos Gkekas <chris.gekas@gmail.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
u8 mode;
mode = wacom->led.groups[index].select;
- if (mode >= 0 && mode < 3)
- return snprintf(buf, PAGE_SIZE, "%d\n", mode);
- else
- return snprintf(buf, PAGE_SIZE, "%d\n", -1);
+ return sprintf(buf, "%d\n", mode < 3 ? mode : -1);
}
#define DEVICE_EKR_ATTR_GROUP(SET_ID) \