MIPS: ralink: Remove check for CONFIG_PCI on non-PCI SoCs
authorJohn Crispin <blogic@openwrt.org>
Wed, 4 Nov 2015 10:50:11 +0000 (11:50 +0100)
committerRalf Baechle <ralf@linux-mips.org>
Wed, 11 Nov 2015 07:38:10 +0000 (08:38 +0100)
The code currently panics if PCI is enabled but the SoC has no PCI bus.
This check is superfluous as the driver only loads if enabled in the
devicetree.

Signed-off-by: John Crispin <blogic@openwrt.org>
Cc: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/11444/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
arch/mips/ralink/mt7620.c

index 55ddf09d867666551de60b36414ae65cd9e769e6..dfb04fcedb042d9b80621ac3197886a1ea3bccda 100644 (file)
@@ -535,9 +535,6 @@ void prom_soc_init(struct ralink_soc_info *soc_info)
                        ralink_soc = MT762X_SOC_MT7620N;
                        name = "MT7620N";
                        soc_info->compatible = "ralink,mt7620n-soc";
-#ifdef CONFIG_PCI
-                       panic("mt7620n is only supported for non pci kernels");
-#endif
                }
        } else if (n0 == MT7620_CHIP_NAME0 && n1 == MT7628_CHIP_NAME1) {
                u32 efuse = __raw_readl(sysc + SYSC_REG_EFUSE_CFG);