ses: Fix problems with simple enclosures
authorJames Bottomley <James.Bottomley@HansenPartnership.com>
Tue, 8 Dec 2015 17:00:31 +0000 (09:00 -0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 3 Mar 2016 23:06:22 +0000 (15:06 -0800)
commit 3417c1b5cb1fdc10261dbed42b05cc93166a78fd upstream.

Simple enclosure implementations (mostly USB) are allowed to return only
page 8 to every diagnostic query.  That really confuses our
implementation because we assume the return is the page we asked for and
end up doing incorrect offsets based on bogus information leading to
accesses outside of allocated ranges.  Fix that by checking the page
code of the return and giving an error if it isn't the one we asked for.
This should fix reported bugs with USB storage by simply refusing to
attach to enclosures that behave like this.  It's also good defensive
practise now that we're starting to see more USB enclosures.

Reported-by: Andrea Gelmini <andrea.gelmini@gelma.net>
Reviewed-by: Ewan D. Milne <emilne@redhat.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/scsi/ses.c

index eba183c428cf3c3fc78e55c356cdd20e615d48d1..b3051fed34f1634985cfd651ca56cef998fdbf46 100644 (file)
@@ -70,6 +70,7 @@ static int ses_probe(struct device *dev)
 static int ses_recv_diag(struct scsi_device *sdev, int page_code,
                         void *buf, int bufflen)
 {
+       int ret;
        unsigned char cmd[] = {
                RECEIVE_DIAGNOSTIC,
                1,              /* Set PCV bit */
@@ -78,9 +79,26 @@ static int ses_recv_diag(struct scsi_device *sdev, int page_code,
                bufflen & 0xff,
                0
        };
+       unsigned char recv_page_code;
 
-       return scsi_execute_req(sdev, cmd, DMA_FROM_DEVICE, buf, bufflen,
+       ret =  scsi_execute_req(sdev, cmd, DMA_FROM_DEVICE, buf, bufflen,
                                NULL, SES_TIMEOUT, SES_RETRIES, NULL);
+       if (unlikely(!ret))
+               return ret;
+
+       recv_page_code = ((unsigned char *)buf)[0];
+
+       if (likely(recv_page_code == page_code))
+               return ret;
+
+       /* successful diagnostic but wrong page code.  This happens to some
+        * USB devices, just print a message and pretend there was an error */
+
+       sdev_printk(KERN_ERR, sdev,
+                   "Wrong diagnostic page; asked for %d got %u\n",
+                   page_code, recv_page_code);
+
+       return -EINVAL;
 }
 
 static int ses_send_diag(struct scsi_device *sdev, int page_code,