IB/ipath: Fix link up LED display
authorArthur Jones <arthur.jones@qlogic.com>
Thu, 17 Apr 2008 04:01:13 +0000 (21:01 -0700)
committerRoland Dreier <rolandd@cisco.com>
Thu, 17 Apr 2008 04:01:13 +0000 (21:01 -0700)
The check for link up was incorrect, thus setting the LED display
inconsistently with the link state.

Signed-off-by: Ralph Campbell <ralph.campbell@qlogic.com>
Signed-off-by: Roland Dreier <rolandd@cisco.com>
drivers/infiniband/hw/ipath/ipath_iba6120.c

index a9fc80409e5745b4515d4dd5a6042d75084eab91..f1447be4cfd32e0f12545a379bb3fda7c17154f9 100644 (file)
@@ -853,7 +853,7 @@ static void ipath_setup_pe_setextled(struct ipath_devdata *dd, u64 lst,
        extctl = dd->ipath_extctrl & ~(INFINIPATH_EXTC_LED1PRIPORT_ON |
                                       INFINIPATH_EXTC_LED2PRIPORT_ON);
 
-       if (ltst & INFINIPATH_IBCS_LT_STATE_LINKUP)
+       if (ltst == INFINIPATH_IBCS_LT_STATE_LINKUP)
                extctl |= INFINIPATH_EXTC_LED2PRIPORT_ON;
        if (lst == INFINIPATH_IBCS_L_STATE_ACTIVE)
                extctl |= INFINIPATH_EXTC_LED1PRIPORT_ON;