clk: ux500: Fix prcmu clocks registration
authorMaxime Coquelin <maxime.coquelin@st.com>
Tue, 26 Mar 2013 14:27:15 +0000 (15:27 +0100)
committerMike Turquette <mturquette@linaro.org>
Wed, 27 Mar 2013 15:35:33 +0000 (08:35 -0700)
In clk_reg_prcmu(), clk->hw.init field is assigned with a
reference local to clk_reg_prcmu() function.

This patch replaces references to clk->hw.init with calls
to __clk_get_name when called after clock registration.

This patch applies on top of v3.9-rc4.

Signed-off-by: Maxime Coquelin <maxime.coquelin@st.com>
Acked-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
[mturquette@linaro.org: resolved trivial merge issues]

drivers/clk/ux500/clk-prcmu.c

index 9d832567c6be606a50c85f5fd5e18af6c1106576..293a28854417374ee6fe3047be1637934eb343a9 100644 (file)
@@ -44,7 +44,7 @@ static void clk_prcmu_unprepare(struct clk_hw *hw)
        struct clk_prcmu *clk = to_clk_prcmu(hw);
        if (prcmu_request_clock(clk->cg_sel, false))
                pr_err("clk_prcmu: %s failed to disable %s.\n", __func__,
-                       hw->init->name);
+                       __clk_get_name(hw->clk));
        else
                clk->is_prepared = 0;
 }
@@ -106,7 +106,7 @@ static int clk_prcmu_opp_prepare(struct clk_hw *hw)
                                                100);
                if (err) {
                        pr_err("clk_prcmu: %s fail req APE OPP for %s.\n",
-                               __func__, hw->init->name);
+                               __func__, __clk_get_name(hw->clk));
                        return err;
                }
                clk->opp_requested = 1;
@@ -130,7 +130,7 @@ static void clk_prcmu_opp_unprepare(struct clk_hw *hw)
 
        if (prcmu_request_clock(clk->cg_sel, false)) {
                pr_err("clk_prcmu: %s failed to disable %s.\n", __func__,
-                       hw->init->name);
+                       __clk_get_name(hw->clk));
                return;
        }
 
@@ -152,7 +152,7 @@ static int clk_prcmu_opp_volt_prepare(struct clk_hw *hw)
                err = prcmu_request_ape_opp_100_voltage(true);
                if (err) {
                        pr_err("clk_prcmu: %s fail req APE OPP VOLT for %s.\n",
-                               __func__, hw->init->name);
+                               __func__, __clk_get_name(hw->clk));
                        return err;
                }
                clk->opp_requested = 1;
@@ -175,7 +175,7 @@ static void clk_prcmu_opp_volt_unprepare(struct clk_hw *hw)
 
        if (prcmu_request_clock(clk->cg_sel, false)) {
                pr_err("clk_prcmu: %s failed to disable %s.\n", __func__,
-                       hw->init->name);
+                       __clk_get_name(hw->clk));
                return;
        }