The newly defined format for the `INSN_CONFIG_DIGITAL_TRIG`
configuration instruction expects 6 data values. Check the length in
`check_insn_config_length()` before calling the comedi subdevice's
`insn_config` handler.
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
if (insn->n == 5)
return 0;
break;
+ case INSN_CONFIG_DIGITAL_TRIG:
+ if (insn->n == 6)
+ return 0;
+ break;
/* by default we allow the insn since we don't have checks for
* all possible cases yet */
default: