The SYSRESET bits in HDMI PLL do not reset the PLL itself, but only
affect the power used for the PLL.
Afaik there is no reason to use the SYSRESET bits, and we don't use it
in the other PLLs, so let's remove the HDMI PLL reset to make the PLL
code simpler and similar to other PLLs.
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
return 0;
}
-static int hdmi_pll_reset(struct hdmi_pll_data *pll)
-{
- /* SYSRESET controlled by power FSM */
- REG_FLD_MOD(pll->base, PLLCTRL_PLL_CONTROL, pll_feat->sys_reset, 3, 3);
-
- /* READ 0x0 reset is in progress */
- if (hdmi_wait_for_bit_change(pll->base, PLLCTRL_PLL_STATUS, 0, 0, 1)
- != 1) {
- DSSERR("Failed to sysreset PLL\n");
- return -ETIMEDOUT;
- }
-
- return 0;
-}
-
int hdmi_pll_enable(struct hdmi_pll_data *pll, struct hdmi_wp_data *wp)
{
u16 r = 0;
if (r)
return r;
- r = hdmi_pll_reset(pll);
- if (r)
- return r;
-
r = hdmi_pll_config(pll);
if (r)
return r;