The IMG PDC watchdog driver heartbeat module parameter has no default so
it is initialised to zero. This results in the following warning during
probe:
imgpdc-wdt
2006000.wdt: Initial timeout out of range! setting max timeout
The module parameter description implies that the default value should
be PDC_WDT_DEF_TIMEOUT, which isn't yet used, so initialise it to that.
Also tweak the heartbeat module parameter description for consistency.
Fixes:
93937669e9b5 ("watchdog: ImgTec PDC Watchdog Timer Driver")
Signed-off-by: James Hogan <james.hogan@imgtec.com>
Cc: Ezequiel Garcia <ezequiel.garcia@imgtec.com>
Cc: Naidu Tellapati <Naidu.Tellapati@imgtec.com>
Cc: Jude Abraham <Jude.Abraham@imgtec.com>
Cc: linux-watchdog@vger.kernel.org
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Wim Van Sebroeck <wim@iguana.be>
#define PDC_WDT_MIN_TIMEOUT 1
#define PDC_WDT_DEF_TIMEOUT 64
-static int heartbeat;
+static int heartbeat = PDC_WDT_DEF_TIMEOUT;
module_param(heartbeat, int, 0);
-MODULE_PARM_DESC(heartbeat, "Watchdog heartbeats in seconds. "
- "(default = " __MODULE_STRING(PDC_WDT_DEF_TIMEOUT) ")");
+MODULE_PARM_DESC(heartbeat, "Watchdog heartbeats in seconds "
+ "(default=" __MODULE_STRING(PDC_WDT_DEF_TIMEOUT) ")");
static bool nowayout = WATCHDOG_NOWAYOUT;
module_param(nowayout, bool, 0);