Current equation on the comment is wrong.
For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1.
Since the linear mapping for PALMAS is not all starting from 0, the equation
on the comment is not useful and misleading. Thus remove it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
#define SMPS_CTRL_MODE_ECO 0x02
#define SMPS_CTRL_MODE_PWM 0x03
-/* These values are derived from the data sheet. And are the number of steps
- * where there is a voltage change, the ranges at beginning and end of register
- * max/min values where there are no change are ommitted.
- *
- * So they are basically (maxV-minV)/stepV
- */
#define PALMAS_SMPS_NUM_VOLTAGES 122
#define PALMAS_SMPS10_NUM_VOLTAGES 2
#define PALMAS_LDO_NUM_VOLTAGES 50