staging: comedi: das1800: allow setting the external trigger polarity
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Fri, 8 Apr 2016 19:42:05 +0000 (12:42 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 29 Apr 2016 05:16:10 +0000 (22:16 -0700)
The external pin TGIN can be used to start and/or stop the analog input
command. Currently the driver only supports negative edge polarity for
this signal.

Add support to allow the user to select positive edge polarity using
the CR_INVERT flag.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/das1800.c

index bfbc2bbbce10d3ccb0461f855a0d7c656dc73b12..875b6f504626e5898913d48a041738a7f74e73fc 100644 (file)
@@ -60,6 +60,9 @@
  * If TRIG_EXT is used for both the start_src and stop_src, the first TGIN
  * trigger starts the command, and the second trigger will stop it. If only
  * one is TRIG_EXT, the first trigger will either stop or start the command.
+ * The external pin TGIN is normally set for negative edge triggering. It
+ * can be set to positive edge with the CR_INVERT flag. If TRIG_EXT is used
+ * for both the start_src and stop_src they must have the same polarity.
  *
  * Minimum conversion speed is limited to 64 microseconds (convert_arg <= 64000)
  * for 'burst' scans. This limitation does not apply for 'paced' scans. The
 #define   CGSL                    0x8
 #define   TGEN                    0x10
 #define   TGSL                    0x20
+#define   TGPL                    0x40
 #define   ATEN                    0x80
 #define DAS1800_CONTROL_B       0x5
 #define   DMA_CH5                 0x1
@@ -671,12 +675,18 @@ static int das1800_ai_cmdtest(struct comedi_device *dev,
            cmd->convert_src != TRIG_TIMER)
                err |= -EINVAL;
 
+       /* the external pin TGIN must use the same polarity */
+       if (cmd->start_src == TRIG_EXT && cmd->stop_src == TRIG_EXT)
+               err |= comedi_check_trigger_arg_is(&cmd->start_arg,
+                                                  cmd->stop_arg);
+
        if (err)
                return 2;
 
        /* Step 3: check if arguments are trivially valid */
 
-       err |= comedi_check_trigger_arg_is(&cmd->start_arg, 0);
+       if (cmd->start_arg == TRIG_NOW)
+               err |= comedi_check_trigger_arg_is(&cmd->start_arg, 0);
 
        if (cmd->convert_src == TRIG_TIMER) {
                err |= comedi_check_trigger_arg_min(&cmd->convert_arg,
@@ -868,6 +878,10 @@ static int das1800_ai_cmd(struct comedi_device *dev,
                control_a |= TGEN | CGSL;
        else /* TRIG_NOW */
                control_a |= CGEN;
+       if (control_a & (ATEN | TGEN)) {
+               if ((cmd->start_arg & CR_INVERT) || (cmd->stop_arg & CR_INVERT))
+                       control_a |= TGPL;
+       }
 
        control_c = das1800_ai_chanspec_bits(s, cmd->chanlist[0]);
        /* set clock source to internal or external */