cifs: Check uniqueid for SMB2+ and return -ESTALE if necessary
authorRoss Lagerwall <ross.lagerwall@citrix.com>
Wed, 2 Dec 2015 14:46:08 +0000 (14:46 +0000)
committerSteve French <sfrench@localhost.localdomain>
Thu, 14 Jan 2016 19:39:11 +0000 (13:39 -0600)
Commit 7196ac113a4f ("Fix to check Unique id and FileType when client
refer file directly.") checks whether the uniqueid of an inode has
changed when getting the inode info, but only when using the UNIX
extensions. Add a similar check for SMB2+, since this can be done
without an extra network roundtrip.

Signed-off-by: Ross Lagerwall <ross.lagerwall@citrix.com>
Signed-off-by: Steve French <smfrench@gmail.com>
fs/cifs/inode.c

index a329f5ba35aad8649ce3f644b9b11913c57cc5f8..aeb26dbfa1bf2dbfb2d111316064d240ef807336 100644 (file)
@@ -814,8 +814,21 @@ cifs_get_inode_info(struct inode **inode, const char *full_path,
                        }
                } else
                        fattr.cf_uniqueid = iunique(sb, ROOT_I);
-       } else
-               fattr.cf_uniqueid = CIFS_I(*inode)->uniqueid;
+       } else {
+               if ((cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) &&
+                   validinum == false && server->ops->get_srv_inum) {
+                       /*
+                        * Pass a NULL tcon to ensure we don't make a round
+                        * trip to the server. This only works for SMB2+.
+                        */
+                       tmprc = server->ops->get_srv_inum(xid,
+                               NULL, cifs_sb, full_path,
+                               &fattr.cf_uniqueid, data);
+                       if (tmprc)
+                               fattr.cf_uniqueid = CIFS_I(*inode)->uniqueid;
+               } else
+                       fattr.cf_uniqueid = CIFS_I(*inode)->uniqueid;
+       }
 
        /* query for SFU type info if supported and needed */
        if (fattr.cf_cifsattrs & ATTR_SYSTEM &&
@@ -856,6 +869,13 @@ cifs_get_inode_info(struct inode **inode, const char *full_path,
        } else {
                /* we already have inode, update it */
 
+               /* if uniqueid is different, return error */
+               if (unlikely(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM &&
+                   CIFS_I(*inode)->uniqueid != fattr.cf_uniqueid)) {
+                       rc = -ESTALE;
+                       goto cgii_exit;
+               }
+
                /* if filetype is different, return error */
                if (unlikely(((*inode)->i_mode & S_IFMT) !=
                    (fattr.cf_mode & S_IFMT))) {