Whilst we don't support the PXN bit at all, so should never encounter a
level 1 section or supersection PTE with it set, it would still be wise
to check both table type bits to resolve any theoretical ambiguity.
Signed-off-by: Robin Murphy <robin.murphy@arm.com>
Signed-off-by: Will Deacon <will.deacon@arm.com>
#define ARM_V7S_PTE_TYPE_CONT_PAGE 0x1
#define ARM_V7S_PTE_IS_VALID(pte) (((pte) & 0x3) != 0)
-#define ARM_V7S_PTE_IS_TABLE(pte, lvl) (lvl == 1 && ((pte) & ARM_V7S_PTE_TYPE_TABLE))
+#define ARM_V7S_PTE_IS_TABLE(pte, lvl) \
+ ((lvl) == 1 && (((pte) & 0x3) == ARM_V7S_PTE_TYPE_TABLE))
/* Page table bits */
#define ARM_V7S_ATTR_XN(lvl) BIT(4 * (2 - (lvl)))