serial/imx: fix IMX UART macro usage to reflect correct processor
authorOskar Schirmer <oskar@scara.com>
Mon, 10 Sep 2012 09:19:35 +0000 (09:19 +0000)
committerSascha Hauer <s.hauer@pengutronix.de>
Wed, 12 Sep 2012 09:46:56 +0000 (11:46 +0200)
Platform dependant UART data refers to MX31 macro for MX35 machines.
For all other machines, macro usage matches machine type.

Though this compiles out to the same result, it looks much like
a typo, so fix it to use the right macros instead.

Signed-off-by: Oskar Schirmer <oskar@scara.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
arch/arm/plat-mxc/devices/platform-imx-uart.c

index 2020d84956c34c4f13662d5e867c064b21ef4dc9..d390f00bd29421e2dbe1d39a2f1c6b7392f7c529 100644 (file)
@@ -87,7 +87,7 @@ const struct imx_imx_uart_1irq_data imx31_imx_uart_data[] __initconst = {
 #ifdef CONFIG_SOC_IMX35
 const struct imx_imx_uart_1irq_data imx35_imx_uart_data[] __initconst = {
 #define imx35_imx_uart_data_entry(_id, _hwid)                          \
-       imx_imx_uart_1irq_data_entry(MX31, _id, _hwid, SZ_16K)
+       imx_imx_uart_1irq_data_entry(MX35, _id, _hwid, SZ_16K)
        imx35_imx_uart_data_entry(0, 1),
        imx35_imx_uart_data_entry(1, 2),
        imx35_imx_uart_data_entry(2, 3),