mpt3sas: Added OEM Gen2 PnP ID branding names
authorSreekanth Reddy <sreekanth.reddy@avagotech.com>
Wed, 11 Nov 2015 12:00:32 +0000 (17:30 +0530)
committerMartin K. Petersen <martin.petersen@oracle.com>
Thu, 12 Nov 2015 00:22:28 +0000 (19:22 -0500)
Added OEM Gen2 PnP ID branding names from mpt2sas driver.

Signed-off-by: Sreekanth Reddy <Sreekanth.Reddy@avagotech.com>
Acked-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/mpt3sas/mpt3sas_base.c
drivers/scsi/mpt3sas/mpt3sas_base.h

index f7f2ab5ecc4f75f8e5e7fe51f2fbb19c101f9985..bec31633be3b370902babc3fd0f2fe5f81411e2f 100644 (file)
@@ -2508,143 +2508,261 @@ mpt3sas_base_put_smid_default(struct MPT3SAS_ADAPTER *ioc, u16 smid)
 }
 
 /**
- * _base_display_intel_branding - Display branding string
+ * _base_display_OEMs_branding - Display branding string
  * @ioc: per adapter object
  *
  * Return nothing.
  */
 static void
-_base_display_intel_branding(struct MPT3SAS_ADAPTER *ioc)
+_base_display_OEMs_branding(struct MPT3SAS_ADAPTER *ioc)
 {
        if (ioc->pdev->subsystem_vendor != PCI_VENDOR_ID_INTEL)
                return;
 
-       switch (ioc->pdev->device) {
-       case MPI25_MFGPAGE_DEVID_SAS3008:
-               switch (ioc->pdev->subsystem_device) {
-               case MPT3SAS_INTEL_RMS3JC080_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_INTEL_RMS3JC080_BRANDING);
-                       break;
-
-               case MPT3SAS_INTEL_RS3GC008_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_INTEL_RS3GC008_BRANDING);
-                       break;
-               case MPT3SAS_INTEL_RS3FC044_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_INTEL_RS3FC044_BRANDING);
-                       break;
-               case MPT3SAS_INTEL_RS3UC080_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_INTEL_RS3UC080_BRANDING);
+       switch (ioc->pdev->subsystem_vendor) {
+       case PCI_VENDOR_ID_INTEL:
+               switch (ioc->pdev->device) {
+               case MPI2_MFGPAGE_DEVID_SAS2008:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT2SAS_INTEL_RMS2LL080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS2LL080_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS2LL040_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS2LL040_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_SSD910_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_SSD910_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                "Intel(R) Controller: Subsystem ID: 0x%X\n",
+                                ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
+               case MPI2_MFGPAGE_DEVID_SAS2308_2:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT2SAS_INTEL_RS25GB008_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RS25GB008_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25JB080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25JB080_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25JB040_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25JB040_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25KB080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25KB080_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25KB040_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25KB040_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25LB040_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25LB040_BRANDING);
+                               break;
+                       case MPT2SAS_INTEL_RMS25LB080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_INTEL_RMS25LB080_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                "Intel(R) Controller: Subsystem ID: 0x%X\n",
+                                ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
+               case MPI25_MFGPAGE_DEVID_SAS3008:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT3SAS_INTEL_RMS3JC080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_INTEL_RMS3JC080_BRANDING);
+                               break;
+
+                       case MPT3SAS_INTEL_RS3GC008_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_INTEL_RS3GC008_BRANDING);
+                               break;
+                       case MPT3SAS_INTEL_RS3FC044_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_INTEL_RS3FC044_BRANDING);
+                               break;
+                       case MPT3SAS_INTEL_RS3UC080_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_INTEL_RS3UC080_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                "Intel(R) Controller: Subsystem ID: 0x%X\n",
+                                ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
                        break;
                default:
                        pr_info(MPT3SAS_FMT
-                               "Intel(R) Controller: Subsystem ID: 0x%X\n",
-                               ioc->name, ioc->pdev->subsystem_device);
+                        "Intel(R) Controller: Subsystem ID: 0x%X\n",
+                        ioc->name, ioc->pdev->subsystem_device);
                        break;
                }
                break;
-       default:
-               pr_info(MPT3SAS_FMT
-                       "Intel(R) Controller: Subsystem ID: 0x%X\n",
-                       ioc->name, ioc->pdev->subsystem_device);
-               break;
-       }
-}
-
-
-
-/**
- * _base_display_dell_branding - Display branding string
- * @ioc: per adapter object
- *
- * Return nothing.
- */
-static void
-_base_display_dell_branding(struct MPT3SAS_ADAPTER *ioc)
-{
-       if (ioc->pdev->subsystem_vendor != PCI_VENDOR_ID_DELL)
-               return;
-
-       switch (ioc->pdev->device) {
-       case MPI25_MFGPAGE_DEVID_SAS3008:
-               switch (ioc->pdev->subsystem_device) {
-               case MPT3SAS_DELL_12G_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_DELL_12G_HBA_BRANDING);
+       case PCI_VENDOR_ID_DELL:
+               switch (ioc->pdev->device) {
+               case MPI2_MFGPAGE_DEVID_SAS2008:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT2SAS_DELL_6GBPS_SAS_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_6GBPS_SAS_HBA_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_PERC_H200_ADAPTER_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_PERC_H200_ADAPTER_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_PERC_H200_INTEGRATED_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_PERC_H200_INTEGRATED_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_PERC_H200_MODULAR_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_PERC_H200_MODULAR_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_PERC_H200_EMBEDDED_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_PERC_H200_EMBEDDED_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_PERC_H200_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_PERC_H200_BRANDING);
+                               break;
+                       case MPT2SAS_DELL_6GBPS_SAS_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_DELL_6GBPS_SAS_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                  "Dell 6Gbps HBA: Subsystem ID: 0x%X\n",
+                                  ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
+                       break;
+               case MPI25_MFGPAGE_DEVID_SAS3008:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT3SAS_DELL_12G_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_DELL_12G_HBA_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                  "Dell 12Gbps HBA: Subsystem ID: 0x%X\n",
+                                  ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
                        break;
                default:
                        pr_info(MPT3SAS_FMT
-                          "Dell 12Gbps HBA: Subsystem ID: 0x%X\n", ioc->name,
+                          "Dell HBA: Subsystem ID: 0x%X\n", ioc->name,
                           ioc->pdev->subsystem_device);
                        break;
                }
                break;
-       default:
-               pr_info(MPT3SAS_FMT
-                       "Dell 12Gbps HBA: Subsystem ID: 0x%X\n", ioc->name,
-                       ioc->pdev->subsystem_device);
-               break;
-       }
-}
-
-/**
- * _base_display_cisco_branding - Display branding string
- * @ioc: per adapter object
- *
- * Return nothing.
- */
-static void
-_base_display_cisco_branding(struct MPT3SAS_ADAPTER *ioc)
-{
-       if (ioc->pdev->subsystem_vendor != PCI_VENDOR_ID_CISCO)
-               return;
-
-       switch (ioc->pdev->device) {
-       case MPI25_MFGPAGE_DEVID_SAS3008:
-               switch (ioc->pdev->subsystem_device) {
-               case MPT3SAS_CISCO_12G_8E_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_CISCO_12G_8E_HBA_BRANDING);
-                       break;
-               case MPT3SAS_CISCO_12G_8I_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                               MPT3SAS_CISCO_12G_8I_HBA_BRANDING);
+       case PCI_VENDOR_ID_CISCO:
+               switch (ioc->pdev->device) {
+               case MPI25_MFGPAGE_DEVID_SAS3008:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT3SAS_CISCO_12G_8E_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_CISCO_12G_8E_HBA_BRANDING);
+                               break;
+                       case MPT3SAS_CISCO_12G_8I_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_CISCO_12G_8I_HBA_BRANDING);
+                               break;
+                       case MPT3SAS_CISCO_12G_AVILA_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                       MPT3SAS_CISCO_12G_AVILA_HBA_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                 "Cisco 12Gbps SAS HBA: Subsystem ID: 0x%X\n",
+                                 ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
                        break;
-               case MPT3SAS_CISCO_12G_AVILA_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+               case MPI25_MFGPAGE_DEVID_SAS3108_1:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT3SAS_CISCO_12G_AVILA_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
                                MPT3SAS_CISCO_12G_AVILA_HBA_BRANDING);
+                               break;
+                       case MPT3SAS_CISCO_12G_COLUSA_MEZZANINE_HBA_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                               MPT3SAS_CISCO_12G_COLUSA_MEZZANINE_HBA_BRANDING
+                               );
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                "Cisco 12Gbps SAS HBA: Subsystem ID: 0x%X\n",
+                                ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
                        break;
                default:
                        pr_info(MPT3SAS_FMT
-                         "Cisco 12Gbps SAS HBA: Subsystem ID: 0x%X\n",
-                         ioc->name, ioc->pdev->subsystem_device);
+                          "Cisco SAS HBA: Subsystem ID: 0x%X\n",
+                          ioc->name, ioc->pdev->subsystem_device);
                        break;
                }
                break;
-       case MPI25_MFGPAGE_DEVID_SAS3108_1:
-               switch (ioc->pdev->subsystem_device) {
-               case MPT3SAS_CISCO_12G_AVILA_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                       MPT3SAS_CISCO_12G_AVILA_HBA_BRANDING);
-                       break;
-               case MPT3SAS_CISCO_12G_COLUSA_MEZZANINE_HBA_SSDID:
-                       pr_info(MPT3SAS_FMT "%s\n", ioc->name,
-                       MPT3SAS_CISCO_12G_COLUSA_MEZZANINE_HBA_BRANDING);
-                       break;
+       case MPT2SAS_HP_3PAR_SSVID:
+               switch (ioc->pdev->device) {
+               case MPI2_MFGPAGE_DEVID_SAS2004:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT2SAS_HP_DAUGHTER_2_4_INTERNAL_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_HP_DAUGHTER_2_4_INTERNAL_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                  "HP 6Gbps SAS HBA: Subsystem ID: 0x%X\n",
+                                  ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
+               case MPI2_MFGPAGE_DEVID_SAS2308_2:
+                       switch (ioc->pdev->subsystem_device) {
+                       case MPT2SAS_HP_2_4_INTERNAL_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_HP_2_4_INTERNAL_BRANDING);
+                               break;
+                       case MPT2SAS_HP_2_4_EXTERNAL_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_HP_2_4_EXTERNAL_BRANDING);
+                               break;
+                       case MPT2SAS_HP_1_4_INTERNAL_1_4_EXTERNAL_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                MPT2SAS_HP_1_4_INTERNAL_1_4_EXTERNAL_BRANDING);
+                               break;
+                       case MPT2SAS_HP_EMBEDDED_2_4_INTERNAL_SSDID:
+                               pr_info(MPT3SAS_FMT "%s\n", ioc->name,
+                                   MPT2SAS_HP_EMBEDDED_2_4_INTERNAL_BRANDING);
+                               break;
+                       default:
+                               pr_info(MPT3SAS_FMT
+                                  "HP 6Gbps SAS HBA: Subsystem ID: 0x%X\n",
+                                  ioc->name, ioc->pdev->subsystem_device);
+                               break;
+                       }
                default:
                        pr_info(MPT3SAS_FMT
-                        "Cisco 12Gbps SAS HBA: Subsystem ID: 0x%X\n",
-                        ioc->name, ioc->pdev->subsystem_device);
+                          "HP SAS HBA: Subsystem ID: 0x%X\n",
+                          ioc->name, ioc->pdev->subsystem_device);
                        break;
                }
-               break;
        default:
-                pr_info(MPT3SAS_FMT
-                       "Cisco 12Gbps SAS HBA: Subsystem ID: 0x%X\n",
-                       ioc->name, ioc->pdev->subsystem_device);
                break;
        }
 }
@@ -2678,9 +2796,7 @@ _base_display_ioc_capabilities(struct MPT3SAS_ADAPTER *ioc)
           (bios_version & 0x0000FF00) >> 8,
            bios_version & 0x000000FF);
 
-       _base_display_intel_branding(ioc);
-       _base_display_dell_branding(ioc);
-       _base_display_cisco_branding(ioc);
+       _base_display_OEMs_branding(ioc);
 
        pr_info(MPT3SAS_FMT "Protocol=(", ioc->name);
 
index b61a7859a4ca24315877ded08eac952290081adb..c92be3c15e4638ada13faa2c661ce96ec46db432 100644 (file)
 /*
  * Intel HBA branding
  */
+#define MPT2SAS_INTEL_RMS25JB080_BRANDING    \
+       "Intel(R) Integrated RAID Module RMS25JB080"
+#define MPT2SAS_INTEL_RMS25JB040_BRANDING    \
+       "Intel(R) Integrated RAID Module RMS25JB040"
+#define MPT2SAS_INTEL_RMS25KB080_BRANDING    \
+       "Intel(R) Integrated RAID Module RMS25KB080"
+#define MPT2SAS_INTEL_RMS25KB040_BRANDING    \
+       "Intel(R) Integrated RAID Module RMS25KB040"
+#define MPT2SAS_INTEL_RMS25LB040_BRANDING      \
+       "Intel(R) Integrated RAID Module RMS25LB040"
+#define MPT2SAS_INTEL_RMS25LB080_BRANDING      \
+       "Intel(R) Integrated RAID Module RMS25LB080"
+#define MPT2SAS_INTEL_RMS2LL080_BRANDING       \
+       "Intel Integrated RAID Module RMS2LL080"
+#define MPT2SAS_INTEL_RMS2LL040_BRANDING       \
+       "Intel Integrated RAID Module RMS2LL040"
+#define MPT2SAS_INTEL_RS25GB008_BRANDING       \
+       "Intel(R) RAID Controller RS25GB008"
+#define MPT2SAS_INTEL_SSD910_BRANDING          \
+       "Intel(R) SSD 910 Series"
+
 #define MPT3SAS_INTEL_RMS3JC080_BRANDING       \
        "Intel(R) Integrated RAID Module RMS3JC080"
 #define MPT3SAS_INTEL_RS3GC008_BRANDING       \
 /*
  * Intel HBA SSDIDs
  */
-#define MPT3SAS_INTEL_RMS3JC080_SSDID  0x3521
-#define MPT3SAS_INTEL_RS3GC008_SSDID   0x3522
-#define MPT3SAS_INTEL_RS3FC044_SSDID   0x3523
-#define MPT3SAS_INTEL_RS3UC080_SSDID    0x3524
+#define MPT2SAS_INTEL_RMS25JB080_SSDID         0x3516
+#define MPT2SAS_INTEL_RMS25JB040_SSDID         0x3517
+#define MPT2SAS_INTEL_RMS25KB080_SSDID         0x3518
+#define MPT2SAS_INTEL_RMS25KB040_SSDID         0x3519
+#define MPT2SAS_INTEL_RMS25LB040_SSDID         0x351A
+#define MPT2SAS_INTEL_RMS25LB080_SSDID         0x351B
+#define MPT2SAS_INTEL_RMS2LL080_SSDID          0x350E
+#define MPT2SAS_INTEL_RMS2LL040_SSDID          0x350F
+#define MPT2SAS_INTEL_RS25GB008_SSDID          0x3000
+#define MPT2SAS_INTEL_SSD910_SSDID             0x3700
+
+#define MPT3SAS_INTEL_RMS3JC080_SSDID          0x3521
+#define MPT3SAS_INTEL_RS3GC008_SSDID           0x3522
+#define MPT3SAS_INTEL_RS3FC044_SSDID           0x3523
+#define MPT3SAS_INTEL_RS3UC080_SSDID           0x3524
 
 /*
  * Dell HBA branding
  */
+#define MPT2SAS_DELL_BRANDING_SIZE                 32
+
+#define MPT2SAS_DELL_6GBPS_SAS_HBA_BRANDING        "Dell 6Gbps SAS HBA"
+#define MPT2SAS_DELL_PERC_H200_ADAPTER_BRANDING    "Dell PERC H200 Adapter"
+#define MPT2SAS_DELL_PERC_H200_INTEGRATED_BRANDING "Dell PERC H200 Integrated"
+#define MPT2SAS_DELL_PERC_H200_MODULAR_BRANDING    "Dell PERC H200 Modular"
+#define MPT2SAS_DELL_PERC_H200_EMBEDDED_BRANDING   "Dell PERC H200 Embedded"
+#define MPT2SAS_DELL_PERC_H200_BRANDING            "Dell PERC H200"
+#define MPT2SAS_DELL_6GBPS_SAS_BRANDING            "Dell 6Gbps SAS"
+
 #define MPT3SAS_DELL_12G_HBA_BRANDING       \
        "Dell 12Gbps HBA"
 
 /*
  * Dell HBA SSDIDs
  */
-#define MPT3SAS_DELL_12G_HBA_SSDID     0x1F46
+#define MPT2SAS_DELL_6GBPS_SAS_HBA_SSDID       0x1F1C
+#define MPT2SAS_DELL_PERC_H200_ADAPTER_SSDID   0x1F1D
+#define MPT2SAS_DELL_PERC_H200_INTEGRATED_SSDID        0x1F1E
+#define MPT2SAS_DELL_PERC_H200_MODULAR_SSDID   0x1F1F
+#define MPT2SAS_DELL_PERC_H200_EMBEDDED_SSDID  0x1F20
+#define MPT2SAS_DELL_PERC_H200_SSDID           0x1F21
+#define MPT2SAS_DELL_6GBPS_SAS_SSDID           0x1F22
+
+#define MPT3SAS_DELL_12G_HBA_SSDID             0x1F46
 
 /*
  * Cisco HBA branding
  */
 #define MPT3SAS_CISCO_12G_8E_HBA_BRANDING              \
-               "Cisco 9300-8E 12G SAS HBA"
+       "Cisco 9300-8E 12G SAS HBA"
 #define MPT3SAS_CISCO_12G_8I_HBA_BRANDING              \
-               "Cisco 9300-8i 12G SAS HBA"
+       "Cisco 9300-8i 12G SAS HBA"
 #define MPT3SAS_CISCO_12G_AVILA_HBA_BRANDING   \
-               "Cisco 12G Modular SAS Pass through Controller"
+       "Cisco 12G Modular SAS Pass through Controller"
 #define MPT3SAS_CISCO_12G_COLUSA_MEZZANINE_HBA_BRANDING                \
-               "UCS C3X60 12G SAS Pass through Controller"
+       "UCS C3X60 12G SAS Pass through Controller"
 /*
  * Cisco HBA SSSDIDs
  */
 #define MPT3_DIAG_BUFFER_IS_RELEASED   (0x02)
 #define MPT3_DIAG_BUFFER_IS_DIAG_RESET (0x04)
 
+/*
+ * HP HBA branding
+ */
+#define MPT2SAS_HP_3PAR_SSVID                0x1590
+
+#define MPT2SAS_HP_2_4_INTERNAL_BRANDING       \
+       "HP H220 Host Bus Adapter"
+#define MPT2SAS_HP_2_4_EXTERNAL_BRANDING       \
+       "HP H221 Host Bus Adapter"
+#define MPT2SAS_HP_1_4_INTERNAL_1_4_EXTERNAL_BRANDING  \
+       "HP H222 Host Bus Adapter"
+#define MPT2SAS_HP_EMBEDDED_2_4_INTERNAL_BRANDING      \
+       "HP H220i Host Bus Adapter"
+#define MPT2SAS_HP_DAUGHTER_2_4_INTERNAL_BRANDING      \
+       "HP H210i Host Bus Adapter"
+
+/*
+ * HO HBA SSDIDs
+ */
+#define MPT2SAS_HP_2_4_INTERNAL_SSDID                  0x0041
+#define MPT2SAS_HP_2_4_EXTERNAL_SSDID                  0x0042
+#define MPT2SAS_HP_1_4_INTERNAL_1_4_EXTERNAL_SSDID     0x0043
+#define MPT2SAS_HP_EMBEDDED_2_4_INTERNAL_SSDID         0x0044
+#define MPT2SAS_HP_DAUGHTER_2_4_INTERNAL_SSDID         0x0046
+
 /*
  * Combined Reply Queue constants,
  * There are twelve Supplemental Reply Post Host Index Registers