[PATCH] ppc64: fix 32-bit signal frame back link
authorPaul Mackerras <paulus@samba.org>
Sat, 30 Apr 2005 17:01:40 +0000 (10:01 -0700)
committerLinus Torvalds <torvalds@ppc970.osdl.org>
Sat, 30 Apr 2005 17:01:40 +0000 (10:01 -0700)
When the kernel creates a signal frame on the user stack, it puts the
old stack pointer value at the beginning so that the signal frame is
linked into the chain of stack frames like any other frame.
Unfortunately, for 32-bit processes we are writing the old stack
pointer as a 64-bit value rather than a 32-bit value, and the process
sees that as a null pointer, since it only looks at the first 32 bits,
which are zero since ppc is bigendian and the stack pointer is below
4GB.  This bug is in SLES9 and RHEL4 too, hence the ccs.

This patch fixes the bug by making the signal code write the old stack
pointer as a u32 instead of an unsigned long.

Signed-off-by: Paul Mackerras <paulus@samba.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
arch/ppc64/kernel/signal32.c

index b0e167db6af9c68f49949d409abc747d3119842f..3c2fa5c284c04ef223c468c2df53f6c7676dc20a 100644 (file)
@@ -657,7 +657,7 @@ static int handle_rt_signal32(unsigned long sig, struct k_sigaction *ka,
 
        /* Save user registers on the stack */
        frame = &rt_sf->uc.uc_mcontext;
-       if (put_user(regs->gpr[1], (unsigned long __user *)newsp))
+       if (put_user(regs->gpr[1], (u32 __user *)newsp))
                goto badframe;
 
        if (vdso32_rt_sigtramp && current->thread.vdso_base) {
@@ -842,7 +842,7 @@ static int handle_signal32(unsigned long sig, struct k_sigaction *ka,
                regs->link = (unsigned long) frame->mctx.tramp;
        }
 
-       if (put_user(regs->gpr[1], (unsigned long __user *)newsp))
+       if (put_user(regs->gpr[1], (u32 __user *)newsp))
                goto badframe;
        regs->gpr[1] = (unsigned long) newsp;
        regs->gpr[3] = sig;