[PATCH] hostap: Fix hw reset after CMDCODE_ACCESS_WRITE timeout
authorAdrian Bunk <bunk@stusta.de>
Mon, 20 Mar 2006 03:21:44 +0000 (19:21 -0800)
committerJohn W. Linville <linville@tuxdriver.com>
Thu, 23 Mar 2006 21:16:57 +0000 (16:16 -0500)
The Coverity checker (CID: 59) noted that the call to prism2_hw_reset()
was dead code. Move prism2_hw_reset() call to a place where it is
actually executed.

Signed-off-by: Adrian Bunk <bunk@stusta.de>
Signed-off-by: Jouni Malinen <jkmaline@cc.hut.fi>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
drivers/net/wireless/hostap/hostap_hw.c

index b1f142d9e232b39cc42f5195cf6fd7b8d11d84ca..328e9a1d13b569da739270f335e683a3001811c9 100644 (file)
@@ -928,15 +928,15 @@ static int hfa384x_set_rid(struct net_device *dev, u16 rid, void *buf, int len)
 
        res = hfa384x_cmd(dev, HFA384X_CMDCODE_ACCESS_WRITE, rid, NULL, NULL);
        up(&local->rid_bap_sem);
+
        if (res) {
                printk(KERN_DEBUG "%s: hfa384x_set_rid: CMDCODE_ACCESS_WRITE "
                       "failed (res=%d, rid=%04x, len=%d)\n",
                       dev->name, res, rid, len);
-               return res;
-       }
 
-       if (res == -ETIMEDOUT)
-               prism2_hw_reset(dev);
+               if (res == -ETIMEDOUT)
+                       prism2_hw_reset(dev);
+       }
 
        return res;
 }