#define BAT_STAT_AC 0x10
#define BAT_STAT_CHARGING 0x20
#define BAT_STAT_DISCHARGING 0x40
+#define BAT_STAT_TRICKLE 0x80
#define BAT_ERR_INFOFAIL 0x02
#define BAT_ERR_OVERVOLTAGE 0x04
static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
{
if (olpc_platform_info.ecver > 0x44) {
- if (ec_byte & BAT_STAT_CHARGING)
+ if (ec_byte & (BAT_STAT_CHARGING | BAT_STAT_TRICKLE))
val->intval = POWER_SUPPLY_STATUS_CHARGING;
else if (ec_byte & BAT_STAT_DISCHARGING)
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
It doesn't matter though -- the EC will return the last-known
information, and it's as if we just ran that _little_ bit faster
and managed to read it out before the battery went away. */
- if (!(ec_byte & BAT_STAT_PRESENT) && psp != POWER_SUPPLY_PROP_PRESENT)
+ if (!(ec_byte & (BAT_STAT_PRESENT | BAT_STAT_TRICKLE)) &&
+ psp != POWER_SUPPLY_PROP_PRESENT)
return -ENODEV;
switch (psp) {
return ret;
break;
case POWER_SUPPLY_PROP_PRESENT:
- val->intval = !!(ec_byte & BAT_STAT_PRESENT);
+ val->intval = !!(ec_byte & (BAT_STAT_PRESENT |
+ BAT_STAT_TRICKLE));
break;
case POWER_SUPPLY_PROP_HEALTH: