EDAC, mv64x60: Fix an error handling path
authorChristophe JAILLET <christophe.jaillet@wanadoo.fr>
Sun, 7 Jan 2018 20:54:00 +0000 (21:54 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 13 Apr 2018 17:48:30 +0000 (19:48 +0200)
[ Upstream commit 68fa24f9121c04ef146b5158f538c8b32f285be5 ]

We should not call edac_mc_del_mc() if a corresponding call to
edac_mc_add_mc() has not been performed yet.

So here, we should go to err instead of err2 to branch at the right
place of the error handling path.

Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Cc: linux-edac <linux-edac@vger.kernel.org>
Link: http://lkml.kernel.org/r/20180107205400.14068-1-christophe.jaillet@wanadoo.fr
Signed-off-by: Borislav Petkov <bp@suse.de>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/edac/mv64x60_edac.c

index cb9b8577acbcc04cd5880f2cc13b398db2814a4a..61c19b81ed81233b9770803e4f33c3fc62755ba0 100644 (file)
@@ -759,7 +759,7 @@ static int mv64x60_mc_err_probe(struct platform_device *pdev)
                /* Non-ECC RAM? */
                printk(KERN_WARNING "%s: No ECC DIMMs discovered\n", __func__);
                res = -ENODEV;
-               goto err2;
+               goto err;
        }
 
        edac_dbg(3, "init mci\n");