power: supply: olpc_battery: correct the temperature units
authorLubomir Rintel <lkundrak@v3.sk>
Fri, 16 Nov 2018 16:23:47 +0000 (17:23 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Sun, 13 Jan 2019 09:01:07 +0000 (10:01 +0100)
commit ed54ffbe554f0902689fd6d1712bbacbacd11376 upstream.

According to [1] and [2], the temperature values are in tenths of degree
Celsius. Exposing the Celsius value makes the battery appear on fire:

  $ upower -i /org/freedesktop/UPower/devices/battery_olpc_battery
  ...
      temperature:         236.9 degrees C

Tested on OLPC XO-1 and OLPC XO-1.75 laptops.

[1] include/linux/power_supply.h
[2] Documentation/power/power_supply_class.txt

Fixes: fb972873a767 ("[BATTERY] One Laptop Per Child power/battery driver")
Cc: stable@vger.kernel.org
Signed-off-by: Lubomir Rintel <lkundrak@v3.sk>
Acked-by: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/power/supply/olpc_battery.c

index 3bc2eea7b3b700ca75d8cbf2dd0ca807c6012d62..62926804949d8ac98ff7d1fb337a39e16e00847b 100644 (file)
@@ -427,14 +427,14 @@ static int olpc_bat_get_property(struct power_supply *psy,
                if (ret)
                        return ret;
 
-               val->intval = (s16)be16_to_cpu(ec_word) * 100 / 256;
+               val->intval = (s16)be16_to_cpu(ec_word) * 10 / 256;
                break;
        case POWER_SUPPLY_PROP_TEMP_AMBIENT:
                ret = olpc_ec_cmd(EC_AMB_TEMP, NULL, 0, (void *)&ec_word, 2);
                if (ret)
                        return ret;
 
-               val->intval = (int)be16_to_cpu(ec_word) * 100 / 256;
+               val->intval = (int)be16_to_cpu(ec_word) * 10 / 256;
                break;
        case POWER_SUPPLY_PROP_CHARGE_COUNTER:
                ret = olpc_ec_cmd(EC_BAT_ACR, NULL, 0, (void *)&ec_word, 2);