* in the entry order.
* TBD double check parallel CPU hotunplug
*/
-static int mce_start(int no_way_out, int *order)
+static int mce_start(int *no_way_out)
{
- int nwo;
+ int order;
int cpus = num_online_cpus();
u64 timeout = (u64)monarch_timeout * NSEC_PER_USEC;
- if (!timeout) {
- *order = -1;
- return no_way_out;
- }
+ if (!timeout)
+ return -1;
- atomic_add(no_way_out, &global_nwo);
+ atomic_add(*no_way_out, &global_nwo);
/*
* global_nwo should be updated before mce_callin
*/
smp_wmb();
- *order = atomic_add_return(1, &mce_callin);
+ order = atomic_add_return(1, &mce_callin);
/*
* Wait for everyone.
while (atomic_read(&mce_callin) != cpus) {
if (mce_timed_out(&timeout)) {
atomic_set(&global_nwo, 0);
- *order = -1;
- return no_way_out;
+ return -1;
}
ndelay(SPINUNIT);
}
* mce_callin should be read before global_nwo
*/
smp_rmb();
- /*
- * Cache the global no_way_out state.
- */
- nwo = atomic_read(&global_nwo);
- /*
- * Monarch starts executing now, the others wait.
- */
- if (*order == 1) {
+ if (order == 1) {
+ /*
+ * Monarch: Starts executing now, the others wait.
+ */
atomic_set(&mce_executing, 1);
- return nwo;
+ } else {
+ /*
+ * Subject: Now start the scanning loop one by one in
+ * the original callin order.
+ * This way when there are any shared banks it will be
+ * only seen by one CPU before cleared, avoiding duplicates.
+ */
+ while (atomic_read(&mce_executing) < order) {
+ if (mce_timed_out(&timeout)) {
+ atomic_set(&global_nwo, 0);
+ return -1;
+ }
+ ndelay(SPINUNIT);
+ }
}
/*
- * Now start the scanning loop one by one
- * in the original callin order.
- * This way when there are any shared banks it will
- * be only seen by one CPU before cleared, avoiding duplicates.
+ * Cache the global no_way_out state.
*/
- while (atomic_read(&mce_executing) < *order) {
- if (mce_timed_out(&timeout)) {
- atomic_set(&global_nwo, 0);
- *order = -1;
- return no_way_out;
- }
- ndelay(SPINUNIT);
- }
- return nwo;
+ *no_way_out = atomic_read(&global_nwo);
+
+ return order;
}
/*
* Establish sequential order between the CPUs entering the machine
* check handler.
*/
- int order = -1;
-
+ int order;
/*
* If no_way_out gets set, there is no safe way to recover from this
* MCE. If tolerant is cranked up, we'll try anyway.
* This way we don't report duplicated events on shared banks
* because the first one to see it will clear it.
*/
- no_way_out = mce_start(no_way_out, &order);
+ order = mce_start(&no_way_out);
for (i = 0; i < banks; i++) {
__clear_bit(i, toclear);
if (!bank[i])