Michał Mirosław's patch (http://patchwork.ozlabs.org/patch/94421/) fixes the
issue (http://patchwork.ozlabs.org/patch/94188/) about not populating FCoE related
flags correctly on vlan devices. However, only NETIF_F_FCOE_CRC is part of the
NETIF_F_ALL_TX_OFFLOADS right now, where weed NETIF_F_FCOE_MTU and NETIF_F_FSO
as well.
Therefore, add NETIF_F_ALL_FCOE to indicate feature flags used by FCoE TX offloads.
These include NETIF_F_FCOE_CRC, NETIF_F_FCOE_MTU, and NETIF_F_FSO and add them to
be part of NETIF_F_ALL_TX_OFFLOADS. This would eventually make sure all FCoE needed
flags are populated properly to vlan devices.
Signed-off-by: Yi Zou <yi.zou@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
#define NETIF_F_ALL_TSO (NETIF_F_TSO | NETIF_F_TSO6 | NETIF_F_TSO_ECN)
+#define NETIF_F_ALL_FCOE (NETIF_F_FCOE_CRC | NETIF_F_FCOE_MTU | \
+ NETIF_F_FSO)
+
#define NETIF_F_ALL_TX_OFFLOADS (NETIF_F_ALL_CSUM | NETIF_F_SG | \
NETIF_F_FRAGLIST | NETIF_F_ALL_TSO | \
NETIF_F_HIGHDMA | \
- NETIF_F_SCTP_CSUM | NETIF_F_FCOE_CRC)
+ NETIF_F_SCTP_CSUM | \
+ NETIF_F_ALL_FCOE)
/*
* If one device supports one of these features, then enable them