acerhdf: return temperature in milidegree instead of degree
authorPeter Feuerer <peter@piie.net>
Tue, 17 Nov 2009 22:07:21 +0000 (14:07 -0800)
committerLen Brown <len.brown@intel.com>
Wed, 25 Nov 2009 05:51:00 +0000 (00:51 -0500)
Return temperature in milidegree instead of degree, as sysfs-api requires
the temperature in milidegree.

Signed-off-by: Peter Feuerer <peter@piie.net>
Tested-by: Borislav Petkov <petkovbb@gmail.com>
Cc: Andreas Mohr <andi@lisas.de>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Len Brown <len.brown@intel.com>
drivers/platform/x86/acerhdf.c

index 0a8f735f6c4a9fd4f79b79ef1c341a6b247be73b..ab64522aaa6433df3e1fcb3c2d92c5633d2c72ad 100644 (file)
@@ -52,7 +52,7 @@
  */
 #undef START_IN_KERNEL_MODE
 
-#define DRV_VER "0.5.17"
+#define DRV_VER "0.5.18"
 
 /*
  * According to the Atom N270 datasheet,
@@ -61,7 +61,7 @@
  * measured by the on-die thermal monitor are within 0 <= Tj <= 90. So,
  * assume 89°C is critical temperature.
  */
-#define ACERHDF_TEMP_CRIT 89
+#define ACERHDF_TEMP_CRIT 89000
 #define ACERHDF_FAN_OFF 0
 #define ACERHDF_FAN_AUTO 1
 
@@ -69,7 +69,7 @@
  * No matter what value the user puts into the fanon variable, turn on the fan
  * at 80 degree Celsius to prevent hardware damage
  */
-#define ACERHDF_MAX_FANON 80
+#define ACERHDF_MAX_FANON 80000
 
 /*
  * Maximum interval between two temperature checks is 15 seconds, as the die
@@ -85,8 +85,8 @@ static int kernelmode;
 #endif
 
 static unsigned int interval = 10;
-static unsigned int fanon = 63;
-static unsigned int fanoff = 58;
+static unsigned int fanon = 63000;
+static unsigned int fanoff = 58000;
 static unsigned int verbose;
 static unsigned int fanstate = ACERHDF_FAN_AUTO;
 static char force_bios[16];
@@ -171,7 +171,7 @@ static int acerhdf_get_temp(int *temp)
        if (ec_read(bios_cfg->tempreg, &read_temp))
                return -EINVAL;
 
-       *temp = read_temp;
+       *temp = read_temp * 1000;
 
        return 0;
 }