cxgb4: FW upgrade fixes
authorArjun Vynipadath <arjun@chelsio.com>
Tue, 30 May 2017 12:36:06 +0000 (18:06 +0530)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 13 Apr 2018 17:48:13 +0000 (19:48 +0200)
[ Upstream commit 26747211486c5bc7dd014c3caab206576e00c0d0 ]

Disable FW_OK flag while flashing Firmware. This will help to fix any
potential mailbox timeouts during Firmware flash.

Grab new devlog parameters after Firmware restart. When we FLASH new
Firmware onto an adapter, the new Firmware may have the Firmware Device Log
located at a different memory address or have a different size for it.

Signed-off-by: Arjun Vynipadath <arjun@chelsio.com>
Signed-off-by: Casey Leedom <leedom@chelsio.com>
Signed-off-by: Ganesh Goudar <ganeshgr@chelsio.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/ethernet/chelsio/cxgb4/t4_hw.c

index 6fd3be69ff21b270c830658245b838934108d45b..24d3918997309804fb607ae5184ce9c4f9e6d95b 100644 (file)
@@ -6185,13 +6185,18 @@ int t4_fw_upgrade(struct adapter *adap, unsigned int mbox,
        if (!t4_fw_matches_chip(adap, fw_hdr))
                return -EINVAL;
 
+       /* Disable FW_OK flag so that mbox commands with FW_OK flag set
+        * wont be sent when we are flashing FW.
+        */
+       adap->flags &= ~FW_OK;
+
        ret = t4_fw_halt(adap, mbox, force);
        if (ret < 0 && !force)
-               return ret;
+               goto out;
 
        ret = t4_load_fw(adap, fw_data, size);
        if (ret < 0)
-               return ret;
+               goto out;
 
        /*
         * Older versions of the firmware don't understand the new
@@ -6202,7 +6207,17 @@ int t4_fw_upgrade(struct adapter *adap, unsigned int mbox,
         * its header flags to see if it advertises the capability.
         */
        reset = ((be32_to_cpu(fw_hdr->flags) & FW_HDR_FLAGS_RESET_HALT) == 0);
-       return t4_fw_restart(adap, mbox, reset);
+       ret = t4_fw_restart(adap, mbox, reset);
+
+       /* Grab potentially new Firmware Device Log parameters so we can see
+        * how healthy the new Firmware is.  It's okay to contact the new
+        * Firmware for these parameters even though, as far as it's
+        * concerned, we've never said "HELLO" to it ...
+        */
+       (void)t4_init_devlog_params(adap);
+out:
+       adap->flags |= FW_OK;
+       return ret;
 }
 
 /**