*hpos horizontal scanout position doesn't need to be corrected
to count the pixels between hactive end and htotal negative.
That is only needed for *vpos to count lines until end of
vblank for the vblank timestamping.
Use hpos as is without correction.
Removes occassional spikes in timestamps of up to 1 scanline
duration, thereby improves accuracy to about +/- 2 usecs instead
of +/- 12 usecs, wrt. true onset time as measured with high
precision equipment on NV-A5.
Signed-off-by: Mario Kleiner <mario.kleiner.de@gmail.com>
Signed-off-by: Ben Skeggs <bskeggs@redhat.com>
if (retry) ndelay(crtc->linedur_ns);
} while (retry--);
- *hpos = calc(args.hblanks, args.hblanke, args.htotal, args.hline);
+ *hpos = args.hline;
*vpos = calc(args.vblanks, args.vblanke, args.vtotal, args.vline);
if (stime) *stime = ns_to_ktime(args.time[0]);
if (etime) *etime = ns_to_ktime(args.time[1]);